Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Instrumentación de prueba y validación de sala limpia

Calibrador de humedad

A transportable humidity and temperature calibration chamber for creating stable setpoints around multiple probes, transmitters and reference sensors.
  • Stable mixed-flow humidity setpoints.
  • Six-probe sealed test chamber.
  • Programmable touch control.
Solicite un presupuesto. Browse productos

Introducción del producto

This bench-top calibrator combines a sealed stainless working chamber with mixed-flow humidity generation, thermoelectric temperature control and an integrated reference channel. Dry and humidified air streams are circulated through the chamber to establish repeatable test conditions without an external compressed-air supply. A front touchscreen manages setpoints, stabilization status and programmed sequences, while interchangeable door sleeves accommodate different probe diameters and keep each insertion point sealed.

Características clave

Dynamic mixed-flow generation supports multiple relative-humidity setpoints in one session.

Thermoelectric chamber control limits temperature-driven errors during humidity comparison.

Six sealed probe ports allow several instruments to share the same controlled condition.

Integrated reference input displays chamber conditions beside the programmed setpoint.

On-screen sequence control reduces repetitive manual changes during multi-point calibration.

Transportable bench enclosure supports laboratory use and on-site instrument checks.

Preocupaciones del producto del cliente

Reliable humidity calibration depends on placing the instrument under test and the reference in the same stable temperature and water-vapor environment while preventing ambient leakage around the probes.

Single-point checks can miss nonlinear sensor error across the working humidity range.Programmable sequences expose every connected instrument to several controlled relative-humidity setpoints.
Temperature mismatch between a probe and its reference can distort relative-humidity results.A circulated thermoelectric chamber holds the devices under test and reference sensor at one controlled temperature.
Calibrating probes one by one consumes technician time and creates inconsistent conditions.Six sealed door ports support simultaneous comparison of several probes in the same working volume.
Different probe diameters can leak ambient air into the chamber.Interchangeable sleeves and blanking plugs seal each occupied or unused port around the actual probe body.

Aplicaciones típicas

Cleanroom humidity probe calibrationEnvironmental transmitter verificationWarehouse and stability-room sensor checksHVAC humidity instrument maintenanceLaboratory reference-hygrometer comparison

Parámetros técnicos

Representative transportable humidity-calibrator construction is listed below; chamber door, probe sleeves, reference interface and operating range can be configured for the calibration workload.

Materiales CorePowder-coated aluminum enclosure, 304 stainless steel chamber, clear polycarbonate door insert and measurement electronics
Panel de espesorTypically 1.5-2.0 mm for aluminum enclosure panels
Ancho efectivoApproximately 450 mm across the bench-top enclosure
Longitud máximaApproximately 406 mm from front chamber door to rear enclosure panel
Acero frente a espesorTypically 1.0-1.5 mm for the stainless chamber liner and port plate
Densidad CoreApproximately 2700 kg/m³ for the aluminum enclosure
Conductividad térmicaApproximately 167-205 W/(m·K) for the aluminum enclosure
Superficie acabadaNeutral light-gray powder coat with a dark graphite control bezel, satin stainless chamber ring and black elastomer probe sleeves
Tipo conjuntoGasketed circular chamber door with six interchangeable probe sleeves, heated sample-loop fittings, USB and Ethernet interfaces
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Six-port probe doorCustom probe-diameter sleevesExternal chilled-mirror reference connectionExtended humidity rangeExtended temperature rangeAutomated multi-point calibration software

Planning a Humidity Calibrator specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto