Calibrateur d'humidité
- Stable mixed-flow humidity setpoints.
- Six-probe sealed test chamber.
- Programmable touch control.
Introduction de produit
This bench-top calibrator combines a sealed stainless working chamber with mixed-flow humidity generation, thermoelectric temperature control and an integrated reference channel. Dry and humidified air streams are circulated through the chamber to establish repeatable test conditions without an external compressed-air supply. A front touchscreen manages setpoints, stabilization status and programmed sequences, while interchangeable door sleeves accommodate different probe diameters and keep each insertion point sealed.
Key Features
Thermoelectric chamber control limits temperature-driven errors during humidity comparison.
Six sealed probe ports allow several instruments to share the same controlled condition.
Integrated reference input displays chamber conditions beside the programmed setpoint.
On-screen sequence control reduces repetitive manual changes during multi-point calibration.
Transportable bench enclosure supports laboratory use and on-site instrument checks.
Préoccupations du client produit
Reliable humidity calibration depends on placing the instrument under test and the reference in the same stable temperature and water-vapor environment while preventing ambient leakage around the probes.
Les applications typiques
Paramètres techniques
Representative transportable humidity-calibrator construction is listed below; chamber door, probe sleeves, reference interface and operating range can be configured for the calibration workload.
| Matériaux de base | Powder-coated aluminum enclosure, 304 stainless steel chamber, clear polycarbonate door insert and measurement electronics |
|---|---|
| Panneau épaisseur | Typically 1.5-2.0 mm for aluminum enclosure panels |
| Largeur effective | Approximately 450 mm across the bench-top enclosure |
| Longueur maximale | Approximately 406 mm from front chamber door to rear enclosure panel |
| Acier face épaisseur | Typically 1.0-1.5 mm for the stainless chamber liner and port plate |
| Densité Core | Approximately 2700 kg/m³ for the aluminum enclosure |
| Conductivité thermique | Approximately 167-205 W/(m·K) for the aluminum enclosure |
| surface finie | Neutral light-gray powder coat with a dark graphite control bezel, satin stainless chamber ring and black elastomer probe sleeves |
| Type joint | Gasketed circular chamber door with six interchangeable probe sleeves, heated sample-loop fittings, USB and Ethernet interfaces |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Humidity Calibrator specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien