Luftfeuchtigkeit Calibrator
- Stable mixed-flow humidity setpoints.
- Six-probe sealed test chamber.
- Programmable touch control.
Produkteinführung
This bench-top calibrator combines a sealed stainless working chamber with mixed-flow humidity generation, thermoelectric temperature control and an integrated reference channel. Dry and humidified air streams are circulated through the chamber to establish repeatable test conditions without an external compressed-air supply. A front touchscreen manages setpoints, stabilization status and programmed sequences, while interchangeable door sleeves accommodate different probe diameters and keep each insertion point sealed.
Key Features
Thermoelectric chamber control limits temperature-driven errors during humidity comparison.
Six sealed probe ports allow several instruments to share the same controlled condition.
Integrated reference input displays chamber conditions beside the programmed setpoint.
On-screen sequence control reduces repetitive manual changes during multi-point calibration.
Transportable bench enclosure supports laboratory use and on-site instrument checks.
Kunden Produktbedenken
Reliable humidity calibration depends on placing the instrument under test and the reference in the same stable temperature and water-vapor environment while preventing ambient leakage around the probes.
Typische Anwendungen
Technische Parameter
Representative transportable humidity-calibrator construction is listed below; chamber door, probe sleeves, reference interface and operating range can be configured for the calibration workload.
| Core Material | Powder-coated aluminum enclosure, 304 stainless steel chamber, clear polycarbonate door insert and measurement electronics |
|---|---|
| Panel Dicke | Typically 1.5-2.0 mm for aluminum enclosure panels |
| Effektive Breite | Approximately 450 mm across the bench-top enclosure |
| Maximale Länge | Approximately 406 mm from front chamber door to rear enclosure panel |
| Stahl facing Dicke | Typically 1.0-1.5 mm for the stainless chamber liner and port plate |
| Kerndichte | Approximately 2700 kg/m³ for the aluminum enclosure |
| Thermische Leitfähigkeit | Approximately 167-205 W/(m·K) for the aluminum enclosure |
| Oberfläche Finish | Neutral light-gray powder coat with a dark graphite control bezel, satin stainless chamber ring and black elastomer probe sleeves |
| Gemeinsamer Typ | Gasketed circular chamber door with six interchangeable probe sleeves, heated sample-loop fittings, USB and Ethernet interfaces |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Humidity Calibrator specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch