Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Ventilador de recuperación de energía

A low-profile ceiling-suspended supply-and-exhaust unit with four sealed round duct spigots, staged filtration and a polymerized-cellulose cross-flow enthalpy core.
  • Four Sealed Round Spigots
  • 227–277 mm Low-Profile Casing
  • Cross-Flow Enthalpy Recovery
  • Bottom-Service Access
Solicite un presupuesto. Browse productos

Introducción del producto

This low-profile ERV arranges supply and extract fans, three panel filters and a plate recovery core in a polymer-coated steel casing intended for suspension above a ceiling. Outdoor and room air travel through isolated passages on opposite sides of the polymerized-cellulose exchanger, where sensible heat and moisture pass through the plates without direct bulk-air mixing. A 5–10 mm expanded-polyurethane lining limits casing heat loss and radiated noise, while the removable underside panel keeps the filters and exchanger reachable after installation.

Características clave

Opposed side connections use rubber-sealed Ø100 or Ø150 mm circular spigots for airtight connection to compact duct branches.

G4 and F8 supply filters provide staged intake-air filtration, while a separate G4 extract filter protects the return side.

The polymerized-cellulose plate pack transfers both heat and humidity across separated cross-flow passages.

Temperature-sensor frost protection pauses the supply fan and uses warm extract air to restore the exchanger before normal operation resumes.

Preocupaciones del producto del cliente

Ceiling-mounted ventilation must recover useful exhaust-air energy without sacrificing duct tightness, winter reliability or practical maintenance access.

A deep ventilation cabinet cannot fit between the structural slab and the finished ceiling.The suspended series uses a 227–277 mm casing height and integrated mounting brackets to conserve ceiling-void depth.
Leaking or incorrectly assigned supply and extract connections undermine balanced air exchange.Four clearly separated side ports with rubber sealing rings create defined, airtight connections for the two airflow circuits.
Filters and recovery media become inaccessible once the unit is enclosed above a completed ceiling.A removable bottom panel gives direct service access to both filter stages, the extract filter and the heat exchanger without removing the side ducts.
Sub-zero intake air can freeze moisture within an enthalpy exchanger and restrict ventilation.The temperature-sensor frost routine temporarily stops intake airflow so warm extract air can thaw the plate surface before automatic restart.

Aplicaciones típicas

Fresh-air support for cleanroom changing and gowning suitesBalanced ventilation for laboratory offices and sample-preparation support roomsOutdoor-air preconditioning for medical-device packaging support zonesHeat and humidity recovery in pharmaceutical ancillary roomsCeiling-void ventilation for quality-control and controlled-storage support spaces

Parámetros técnicos

Common construction dimensions and material ranges for this suspended four-port energy recovery ventilator are listed below.

Materiales CorePolymerized-cellulose plate cross-flow enthalpy exchanger with 5–10 mm expanded-polyurethane casing insulation
Panel de espesor5–10 mm expanded-polyurethane internal insulation
Ancho efectivo704–754 mm overall casing width across the suspended series
Longitud máxima854–1024 mm overall casing length across the suspended series
Acero frente a espesor0.7–1.0 mm polymer-coated steel casing sheet
Densidad CoreApproximately 30–40 kg/m³ for the expanded-polyurethane casing insulation
Conductividad térmicaApproximately 0.019–0.028 W/(m·K) for the expanded-polyurethane casing insulation
Superficie acabadaWhite polymer-coated steel casing with galvanized round spigots and black rubber sealing rings
Tipo conjuntoFour side-mounted Ø100 or Ø150 mm round spigots with rubber seals and a gasketed underside service panel
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Ø100 or Ø150 mm duct-connection configurationsLeft-hand or right-hand service-side arrangementMechanical three-speed switch or external speed-controller packageRemovable summer block for ventilation without energy exchange