Ventilateur de récupération d'énergie
- Four Sealed Round Spigots
- 227–277 mm Low-Profile Casing
- Cross-Flow Enthalpy Recovery
- Bottom-Service Access
Introduction de produit
This low-profile ERV arranges supply and extract fans, three panel filters and a plate recovery core in a polymer-coated steel casing intended for suspension above a ceiling. Outdoor and room air travel through isolated passages on opposite sides of the polymerized-cellulose exchanger, where sensible heat and moisture pass through the plates without direct bulk-air mixing. A 5–10 mm expanded-polyurethane lining limits casing heat loss and radiated noise, while the removable underside panel keeps the filters and exchanger reachable after installation.
Key Features
G4 and F8 supply filters provide staged intake-air filtration, while a separate G4 extract filter protects the return side.
The polymerized-cellulose plate pack transfers both heat and humidity across separated cross-flow passages.
Temperature-sensor frost protection pauses the supply fan and uses warm extract air to restore the exchanger before normal operation resumes.
Préoccupations du client produit
Ceiling-mounted ventilation must recover useful exhaust-air energy without sacrificing duct tightness, winter reliability or practical maintenance access.
Les applications typiques
Paramètres techniques
Common construction dimensions and material ranges for this suspended four-port energy recovery ventilator are listed below.
| Matériaux de base | Polymerized-cellulose plate cross-flow enthalpy exchanger with 5–10 mm expanded-polyurethane casing insulation |
|---|---|
| Panneau épaisseur | 5–10 mm expanded-polyurethane internal insulation |
| Largeur effective | 704–754 mm overall casing width across the suspended series |
| Longueur maximale | 854–1024 mm overall casing length across the suspended series |
| Acier face épaisseur | 0.7–1.0 mm polymer-coated steel casing sheet |
| Densité Core | Approximately 30–40 kg/m³ for the expanded-polyurethane casing insulation |
| Conductivité thermique | Approximately 0.019–0.028 W/(m·K) for the expanded-polyurethane casing insulation |
| surface finie | White polymer-coated steel casing with galvanized round spigots and black rubber sealing rings |
| Type joint | Four side-mounted Ø100 or Ø150 mm round spigots with rubber seals and a gasketed underside service panel |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Energy Recovery Ventilator specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien