เครื่องระบายอากาศกู้คืนพลังงาน
- Four Sealed Round Spigots
- 227–277 mm Low-Profile Casing
- Cross-Flow Enthalpy Recovery
- Bottom-Service Access
การแนะนําสินค้า
This low-profile ERV arranges supply and extract fans, three panel filters and a plate recovery core in a polymer-coated steel casing intended for suspension above a ceiling. Outdoor and room air travel through isolated passages on opposite sides of the polymerized-cellulose exchanger, where sensible heat and moisture pass through the plates without direct bulk-air mixing. A 5–10 mm expanded-polyurethane lining limits casing heat loss and radiated noise, while the removable underside panel keeps the filters and exchanger reachable after installation.
คุณสมบัติที่สําคัญ
G4 and F8 supply filters provide staged intake-air filtration, while a separate G4 extract filter protects the return side.
The polymerized-cellulose plate pack transfers both heat and humidity across separated cross-flow passages.
Temperature-sensor frost protection pauses the supply fan and uses warm extract air to restore the exchanger before normal operation resumes.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
Ceiling-mounted ventilation must recover useful exhaust-air energy without sacrificing duct tightness, winter reliability or practical maintenance access.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
Common construction dimensions and material ranges for this suspended four-port energy recovery ventilator are listed below.
| วัสดุหลัก | Polymerized-cellulose plate cross-flow enthalpy exchanger with 5–10 mm expanded-polyurethane casing insulation |
|---|---|
| ความหนาของแผง | 5–10 mm expanded-polyurethane internal insulation |
| ความกว้างที่มีประสิทธิภาพ | 704–754 mm overall casing width across the suspended series |
| ความยาวสูงสุด | 854–1024 mm overall casing length across the suspended series |
| ความหนาของเหล็กหันหน้า | 0.7–1.0 mm polymer-coated steel casing sheet |
| ความหนาแน่นหลัก | Approximately 30–40 kg/m³ for the expanded-polyurethane casing insulation |
| การนําความร้อน | Approximately 0.019–0.028 W/(m·K) for the expanded-polyurethane casing insulation |
| เสร็จสิ้นพื้นผิว | White polymer-coated steel casing with galvanized round spigots and black rubber sealing rings |
| ประเภทร่วม | Four side-mounted Ø100 or Ø150 mm round spigots with rubber seals and a gasketed underside service panel |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Planning a Energy Recovery Ventilator specification?
ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

ภาษาอังกฤษ
ภาษาเยอรมัน
ภาษาอาหรับ
ฝรั่งเศส
ภาษาอินโดนีเซีย
ภาษาญี่ปุ่น
ภาษาเกาหลี
ภาษามาเลย์
ภาษาโปรตุเกส
ภาษารัสเซีย
ภาษาสเปน
ภาษาไทยปัจจุบัน
ภาษาตุรกี
ภาษาเวียดนาม