Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Equipos de flujo laminar y contención / Closed Restricted Access Barrier System
Equipos de flujo laminar y contención

Sistema de barrera de acceso restringido

An enclosed RABS with controlled internal airflow, glove-access panels and interlocked doors that provides greater process separation than an open barrier.
  • Enclosed Glazed Barrier
  • Controlled Internal Airflow
  • Interlocked Access Doors
  • Glove-Port Interventions
Solicite un presupuesto. Browse productos

Introducción del producto

The closed RABS forms a more complete enclosure around the aseptic process than an open RABS. Rigid panels, sealed lower interfaces and closed doors define the work zone, while filtered air is supplied and returned through the barrier system. Operators intervene through glove ports and use interlocked doors only for controlled setup or maintenance. The system is not automatically equivalent to a gas-tight isolator; its chamber leakage, cleaning and bio-decontamination approach depend on the selected construction.

Características clave

Closed glazed walls define a controlled internal process-air volume.

Supply and return modules manage airflow within the barrier enclosure.

Interlocked doors reduce simultaneous openings along the process line.

Glove panels support intervention while the main doors stay closed.

Sealed lower skirts connect the barrier to machine frames and conveyor openings.

Preocupaciones del producto del cliente

A closed RABS must keep doors, machine interfaces and internal airflow coordinated without claiming the gas-tight performance of an isolator.

Room air enters through gaps around machine bases.Custom lower skirts and flexible seals close the interface to the equipment frame.
Multiple doors are opened during one intervention.Door interlocks and defined glove positions reduce unnecessary barrier opening.
Internal heat builds around the process equipment.Dedicated supply and return sections manage the enclosed air volume.
The enclosure is described as gas-tight without suitable construction.The page distinguishes closed RABS separation from pressure-tight isolator containment.

Aplicaciones típicas

Aseptic filling linesSterile closure handlingOpen product conveyor protectionBarrier retrofit around critical equipment

Parámetros técnicos

Typical configurable construction ranges for a closed restricted access barrier system are listed below.

Materiales CoreSUS316L modular barrier frame with laminated safety glass, CSM gloves and integrated supply-return plenums
Panel de espesor40-80 mm framed barrier and airflow sections
Ancho efectivo1500-6000 mm protected line width
Longitud máximaUp to 25000 mm closed barrier length
Acero frente a espesor1.5-2.0 mm stainless lower skirts, doors and plenum skins
Densidad CoreApproximately 2500 kg/m³ for laminated safety-glass barrier panels
Conductividad térmica0.8-1.0 W/(m·K) for laminated safety glass
Superficie acabadaFine-brushed SUS316L with flush laminated glazing and sealed lower interfaces
Tipo conjuntoGasketed modular barrier joints with interlocked doors, sealed machine interfaces and return-air plenums
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Active filtered recirculationInterlocked glove and service doorsAutomated door status monitoringIntegrated cleaning and environmental ports

Planning a Closed Restricted Access Barrier System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto