Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement d'écoulement et de confinement laminaires / Closed Restricted Access Barrier System
Équipement d'écoulement et de confinement laminaires

Système de barrière d'accès restreint fermé par

An enclosed RABS with controlled internal airflow, glove-access panels and interlocked doors that provides greater process separation than an open barrier.
  • Enclosed Glazed Barrier
  • Controlled Internal Airflow
  • Interlocked Access Doors
  • Glove-Port Interventions
Demander un devis. Browse les produits

Introduction de produit

The closed RABS forms a more complete enclosure around the aseptic process than an open RABS. Rigid panels, sealed lower interfaces and closed doors define the work zone, while filtered air is supplied and returned through the barrier system. Operators intervene through glove ports and use interlocked doors only for controlled setup or maintenance. The system is not automatically equivalent to a gas-tight isolator; its chamber leakage, cleaning and bio-decontamination approach depend on the selected construction.

Key Features

Closed glazed walls define a controlled internal process-air volume.

Supply and return modules manage airflow within the barrier enclosure.

Interlocked doors reduce simultaneous openings along the process line.

Glove panels support intervention while the main doors stay closed.

Sealed lower skirts connect the barrier to machine frames and conveyor openings.

Préoccupations du client produit

A closed RABS must keep doors, machine interfaces and internal airflow coordinated without claiming the gas-tight performance of an isolator.

Room air enters through gaps around machine bases.Custom lower skirts and flexible seals close the interface to the equipment frame.
Multiple doors are opened during one intervention.Door interlocks and defined glove positions reduce unnecessary barrier opening.
Internal heat builds around the process equipment.Dedicated supply and return sections manage the enclosed air volume.
The enclosure is described as gas-tight without suitable construction.The page distinguishes closed RABS separation from pressure-tight isolator containment.

Les applications typiques

Aseptic filling linesSterile closure handlingOpen product conveyor protectionBarrier retrofit around critical equipment

Paramètres techniques

Typical configurable construction ranges for a closed restricted access barrier system are listed below.

Matériaux de baseSUS316L modular barrier frame with laminated safety glass, CSM gloves and integrated supply-return plenums
Panneau épaisseur40-80 mm framed barrier and airflow sections
Largeur effective1500-6000 mm protected line width
Longueur maximaleUp to 25000 mm closed barrier length
Acier face épaisseur1.5-2.0 mm stainless lower skirts, doors and plenum skins
Densité CoreApproximately 2500 kg/m³ for laminated safety-glass barrier panels
Conductivité thermique0.8-1.0 W/(m·K) for laminated safety glass
surface finieFine-brushed SUS316L with flush laminated glazing and sealed lower interfaces
Type jointGasketed modular barrier joints with interlocked doors, sealed machine interfaces and return-air plenums
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Active filtered recirculationInterlocked glove and service doorsAutomated door status monitoringIntegrated cleaning and environmental ports

Planning a Closed Restricted Access Barrier System specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact