Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Control de salas limpias y sistemas de monitoreo ambiental

Z Sistema SCADA de sala limpia

An industrial supervisory platform that visualizes cleanroom HVAC and utility processes, records operating data and issues controlled commands to PLC-based equipment.
  • Real-Time Process Graphics
  • PLC Data Acquisition
  • Historian and Events
  • Controlled Remote Commands
Solicite un presupuesto. Browse productos

Introducción del producto

The SCADA layer communicates with PLCs and intelligent field devices rather than replacing their deterministic control. Process graphics display AHUs, pressure cascades, chilled water, compressed gases and production-support utilities with live operating values. Alarm summaries, sequence-of-events records and historical plots allow engineering staff to diagnose a change from the same workstation. Redundant network and server arrangements can be used where supervisory availability must continue through a hardware outage.

Características clave

Animated process diagrams connect live values to the physical cleanroom equipment sequence.

Industrial drivers acquire PLC tags over Ethernet without slowing local controller execution.

Historian charts correlate fan, valve, pressure and alarm events on a common time base.

Command confirmation and user permissions protect critical equipment from unintended operation.

Preocupaciones del producto del cliente

A cleanroom SCADA system must present complex automation clearly while keeping machine and room control stable at the PLC level.

Operators see tag numbers but cannot relate them to the air system.Equipment-oriented graphics place each live tag on the corresponding fan, damper, coil or room.
A control response cannot be reconstructed after an excursion.Synchronized events and high-resolution historian trends preserve the operating sequence.
Supervisory commands bypass operating safeguards.SCADA writes are limited to PLC-approved command and setpoint objects with confirmation prompts.
A single workstation failure removes plant visibility.Client-server deployment and optional redundant servers maintain access from alternate operator stations.

Aplicaciones típicas

Cleanroom HVAC supervisionProcess utility monitoringCentral plant visualizationMulti-line manufacturing support

Parámetros técnicos

Typical industrial SCADA cabinet and workstation construction values are provided below.

Materiales CorePowder-coated steel cabinet with industrial computer, FR-4 interface cards and copper network hardware
Panel de espesor250-500 mm cabinet depth
Ancho efectivo600-1200 mm cabinet width
Longitud máximaHasta 2200 mm de altura del gabinete
Acero frente a espesor1.5-2.0 mm powder-coated steel panels
Densidad Core7800-8050 kg/m³ for steel cabinet components
Conductividad térmica45-60 W/(m·K) for steel structural panels
Superficie acabadaTextured RAL 7035-style powder coat with black industrial display bezels
Tipo conjuntoModular floor cabinet with gasketed doors, managed Ethernet switches and serviceable terminal sections
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Dual redundant SCADA serversHistorian database serverLarge-format operator video wallOPC UA connectivity

Planning a Cleanroom SCADA System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto