Inicio / Productos / Equipos de HVAC y manejo de aire para salas limpias / Cleanroom Direct-Expansion Air Conditioning Unit
Equipos de HVAC y manejo de aire para salas limpias

Unidad de aire acondicionado de expansión directa para sala limpia

A cleanroom air-conditioning package that uses a refrigerant evaporator coil for direct sensible cooling and dehumidification without a chilled-water circuit.
  • Direct Refrigerant Cooling
  • Matched Condensing System
  • Controlled Dehumidification
  • Cleanroom Filter Staging
Solicite un presupuesto. Browse productos

Introducción del producto

The cleanroom direct-expansion air-conditioning unit combines a refrigerant evaporator coil with cleanable filters, a drainable condensate section and variable-speed supply fan. A matched outdoor condensing unit or remote condenser rejects heat without requiring a central chilled-water plant. Multiple compressor stages or inverter capacity allow the coil to follow varying cleanroom load, while reheat can stabilize room temperature during dehumidification. Refrigerant piping, oil return and coil distribution are designed for the selected distance and lift.

Características clave

Direct refrigerant expansion removes the intermediate chilled-water loop for smaller independent cleanroom systems.

Variable or multi-stage compressor capacity reduces cycling under partial sensible load.

A drainable insulated coil section contains condensate produced during moisture removal.

Reheat and fan-speed control support temperature stability during latent operation.

Preocupaciones del producto del cliente

DX systems must match refrigerant capacity, air volume and coil temperature closely to avoid cycling, water carryover and unstable humidity.

A single large compressor repeatedly starts and stops at low cleanroom load.Inverter or staged compressors modulate closer to the active sensible and latent demand.
An unevenly fed evaporator leaves parts of the coil warm and reduces dehumidification.Matched distributors and expansion control maintain stable refrigerant feed across circuits.
Condensate is carried downstream during high latent load.Proper coil face velocity, eliminator clearance and a full drain pan control water.
Long refrigerant piping causes oil-return and capacity problems.Pipe size, traps and allowable lift are selected for the matched compressor and circuit.

Aplicaciones típicas

Independent cleanroom suitesMedical-device assembly roomsSmall pharmaceutical laboratoriesElectronics test areasCleanroom retrofit projects

Parámetros técnicos

Representative casing values for a cleanroom DX air-conditioning unit are shown below.

Materiales CoreClosed-cell polyurethane insulation in double-skin indoor-unit panels
Panel de espesor40–60 mm insulated casing
Ancho efectivo700–2400 mm nominal indoor-unit width
Longitud máximaUp to 5500 mm including filters, evaporator, reheat and fan
Acero frente a espesor0.6–1.0 mm coated casing sheet
Densidad Core40–45 kg/m³ closed-cell polyurethane
Conductividad térmica0.022–0.026 W/(m·K) for panel insulation
Superficie acabadaPowder-coated outer casing with galvanized or stainless wet-section liner
Tipo conjuntoGasketed low-leakage panels with brazed refrigerant headers and flexible duct collars
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Air-cooled or water-cooled condensing unitFixed-stage or inverter compressorHot-gas, electric or hot-water reheatRemote controller and building-management interface