Accueil / Produits / Salle blanche HVAC et équipement de manutention de l'air / Cleanroom Direct-Expansion Air Conditioning Unit
Salle blanche HVAC et équipement de manutention de l'air

Cleanroom Unité de climatisation à extension directe

A cleanroom air-conditioning package that uses a refrigerant evaporator coil for direct sensible cooling and dehumidification without a chilled-water circuit.
  • Direct Refrigerant Cooling
  • Matched Condensing System
  • Controlled Dehumidification
  • Cleanroom Filter Staging
Demander un devis. Browse les produits

Introduction de produit

The cleanroom direct-expansion air-conditioning unit combines a refrigerant evaporator coil with cleanable filters, a drainable condensate section and variable-speed supply fan. A matched outdoor condensing unit or remote condenser rejects heat without requiring a central chilled-water plant. Multiple compressor stages or inverter capacity allow the coil to follow varying cleanroom load, while reheat can stabilize room temperature during dehumidification. Refrigerant piping, oil return and coil distribution are designed for the selected distance and lift.

Key Features

Direct refrigerant expansion removes the intermediate chilled-water loop for smaller independent cleanroom systems.

Variable or multi-stage compressor capacity reduces cycling under partial sensible load.

A drainable insulated coil section contains condensate produced during moisture removal.

Reheat and fan-speed control support temperature stability during latent operation.

Préoccupations du client produit

DX systems must match refrigerant capacity, air volume and coil temperature closely to avoid cycling, water carryover and unstable humidity.

A single large compressor repeatedly starts and stops at low cleanroom load.Inverter or staged compressors modulate closer to the active sensible and latent demand.
An unevenly fed evaporator leaves parts of the coil warm and reduces dehumidification.Matched distributors and expansion control maintain stable refrigerant feed across circuits.
Condensate is carried downstream during high latent load.Proper coil face velocity, eliminator clearance and a full drain pan control water.
Long refrigerant piping causes oil-return and capacity problems.Pipe size, traps and allowable lift are selected for the matched compressor and circuit.

Les applications typiques

Independent cleanroom suitesMedical-device assembly roomsSmall pharmaceutical laboratoriesElectronics test areasCleanroom retrofit projects

Paramètres techniques

Representative casing values for a cleanroom DX air-conditioning unit are shown below.

Matériaux de baseClosed-cell polyurethane insulation in double-skin indoor-unit panels
Panneau épaisseur40–60 mm insulated casing
Largeur effective700–2400 mm nominal indoor-unit width
Longueur maximaleUp to 5500 mm including filters, evaporator, reheat and fan
Acier face épaisseur0.6–1.0 mm coated casing sheet
Densité Core40–45 kg/m³ closed-cell polyurethane
Conductivité thermique0.022–0.026 W/(m·K) for panel insulation
surface finiePowder-coated outer casing with galvanized or stainless wet-section liner
Type jointGasketed low-leakage panels with brazed refrigerant headers and flexible duct collars
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Air-cooled or water-cooled condensing unitFixed-stage or inverter compressorHot-gas, electric or hot-water reheatRemote controller and building-management interface