Beranda / Produk / Cleanroom HVAC dan Peralatan Penanganan Udara / Cleanroom Direct-Expansion Air Conditioning Unit
Cleanroom HVAC dan Peralatan Penanganan Udara

Cleanroom Unit Pendingin Udara Langsung-Expansi

A cleanroom air-conditioning package that uses a refrigerant evaporator coil for direct sensible cooling and dehumidification without a chilled-water circuit.
  • Direct Refrigerant Cooling
  • Matched Condensing System
  • Controlled Dehumidification
  • Cleanroom Filter Staging
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The cleanroom direct-expansion air-conditioning unit combines a refrigerant evaporator coil with cleanable filters, a drainable condensate section and variable-speed supply fan. A matched outdoor condensing unit or remote condenser rejects heat without requiring a central chilled-water plant. Multiple compressor stages or inverter capacity allow the coil to follow varying cleanroom load, while reheat can stabilize room temperature during dehumidification. Refrigerant piping, oil return and coil distribution are designed for the selected distance and lift.

Fitur utama:

Direct refrigerant expansion removes the intermediate chilled-water loop for smaller independent cleanroom systems.

Variable or multi-stage compressor capacity reduces cycling under partial sensible load.

A drainable insulated coil section contains condensate produced during moisture removal.

Reheat and fan-speed control support temperature stability during latent operation.

Kekhawatiran produk pelanggan

DX systems must match refrigerant capacity, air volume and coil temperature closely to avoid cycling, water carryover and unstable humidity.

A single large compressor repeatedly starts and stops at low cleanroom load.Inverter or staged compressors modulate closer to the active sensible and latent demand.
An unevenly fed evaporator leaves parts of the coil warm and reduces dehumidification.Matched distributors and expansion control maintain stable refrigerant feed across circuits.
Condensate is carried downstream during high latent load.Proper coil face velocity, eliminator clearance and a full drain pan control water.
Long refrigerant piping causes oil-return and capacity problems.Pipe size, traps and allowable lift are selected for the matched compressor and circuit.

Aplikasi yang Tipis

Independent cleanroom suitesRuang perakitan peralatan medisSmall pharmaceutical laboratoriesElectronics test areasCleanroom retrofit projects

Parameter teknis

Representative casing values for a cleanroom DX air-conditioning unit are shown below.

Bahan intiClosed-cell polyurethane insulation in double-skin indoor-unit panels
Ketebalan Panel (Panel Thickness)40–60 mm insulated casing
Efektif lebar700–2400 mm nominal indoor-unit width
Panjang maksimumUp to 5500 mm including filters, evaporator, reheat and fan
Baja menghadap ketebalan0.6–1.0 mm coated casing sheet
Kepadatan inti (core density)40–45 kg/m³ closed-cell polyurethane
Konduktivitas Termal (Thermal Conductivity)0.022–0.026 W/(m·K) for panel insulation
Permukaan selesaiPowder-coated outer casing with galvanized or stainless wet-section liner
Jenis BersamaGasketed low-leakage panels with brazed refrigerant headers and flexible duct collars
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Air-cooled or water-cooled condensing unitFixed-stage or inverter compressorHot-gas, electric or hot-water reheatRemote controller and building-management interface

Planning a Cleanroom Direct-Expansion Air Conditioning Unit specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.