クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / クリーンルーム HVAC および空気処理装置 / Cleanroom Direct-Expansion Air Conditioning Unit
クリーンルーム HVAC および空気処理装置

クリーンルームの直接拡張型空調ユニット

A cleanroom air-conditioning package that uses a refrigerant evaporator coil for direct sensible cooling and dehumidification without a chilled-water circuit.
  • Direct Refrigerant Cooling
  • Matched Condensing System
  • Controlled Dehumidification
  • Cleanroom Filter Staging
見積もりリクエスト 製品案内

商品紹介

The cleanroom direct-expansion air-conditioning unit combines a refrigerant evaporator coil with cleanable filters, a drainable condensate section and variable-speed supply fan. A matched outdoor condensing unit or remote condenser rejects heat without requiring a central chilled-water plant. Multiple compressor stages or inverter capacity allow the coil to follow varying cleanroom load, while reheat can stabilize room temperature during dehumidification. Refrigerant piping, oil return and coil distribution are designed for the selected distance and lift.

主要な特徴

Direct refrigerant expansion removes the intermediate chilled-water loop for smaller independent cleanroom systems.

Variable or multi-stage compressor capacity reduces cycling under partial sensible load.

A drainable insulated coil section contains condensate produced during moisture removal.

Reheat and fan-speed control support temperature stability during latent operation.

お客様の製品に関する懸念事項

DX systems must match refrigerant capacity, air volume and coil temperature closely to avoid cycling, water carryover and unstable humidity.

A single large compressor repeatedly starts and stops at low cleanroom load.Inverter or staged compressors modulate closer to the active sensible and latent demand.
An unevenly fed evaporator leaves parts of the coil warm and reduces dehumidification.Matched distributors and expansion control maintain stable refrigerant feed across circuits.
Condensate is carried downstream during high latent load.Proper coil face velocity, eliminator clearance and a full drain pan control water.
Long refrigerant piping causes oil-return and capacity problems.Pipe size, traps and allowable lift are selected for the matched compressor and circuit.

典型的な用途

Independent cleanroom suitesMedical-device assembly roomsSmall pharmaceutical laboratoriesElectronics test areasCleanroom retrofit projects

技術的なパラメータ

Representative casing values for a cleanroom DX air-conditioning unit are shown below.

コア材料Closed-cell polyurethane insulation in double-skin indoor-unit panels
パネルの厚さ40–60 mm insulated casing
有効幅700–2400 mm nominal indoor-unit width
最大長さUp to 5500 mm including filters, evaporator, reheat and fan
鋼鉄の厚さを直面する0.6–1.0 mm coated casing sheet
コア密度40–45 kg/m³ closed-cell polyurethane
熱伝導率0.022–0.026 W/(m·K) for panel insulation
表面仕上げPowder-coated outer casing with galvanized or stainless wet-section liner
ジョイントタイプGasketed low-leakage panels with brazed refrigerant headers and flexible duct collars
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Air-cooled or water-cooled condensing unitFixed-stage or inverter compressorHot-gas, electric or hot-water reheatRemote controller and building-management interface

Planning a Cleanroom Direct-Expansion Air Conditioning Unit specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat