Techo de suministro limpio Ward
- Four-Module Ward Array
- Room-Side Filter Access
- Perforated Mixing Diffusers
- Independent Top Duct Inlets
Introducción del producto
The clean ward supply ceiling combines four independent terminal filter housings in a compact square 2-by-2 array for hospital ward bed zones and other healthcare rooms requiring filtered ceiling supply. Each shallow powder-coated steel plenum has its own top circular duct collar, retained H14 HEPA cartridge and perforated room-side diffuser. Natural-anodized aluminum rails join the modules beneath one continuous perimeter trim, while corner suspension lugs support coordinated installation above the finished ceiling. The arrangement provides broad turbulent-mixing supply without the lighting, surgical-lamp opening or large central compensation device used on an operating-room canopy.
Características clave
Hinged perforated diffuser panels provide clean-side access to the filter retaining rails, seal interfaces and test points.
A separate circular inlet above each plenum reduces dependence on one deep common box and supports branch balancing.
Powder-coated exposed faces, slim anodized rails and concealed grille fasteners create wipeable room-side surfaces.
Preocupaciones del producto del cliente
A ward supply terminal must deliver clean air across the occupied bed zone while fitting limited ceiling space and remaining serviceable without dismantling the complete array.
Aplicaciones típicas
Parámetros técnicos
Typical configurable construction values for a compact four-module clean ward supply ceiling are listed below.
| Materiales Core | Four H14 mini-pleat HEPA cartridges in RAL 9010 powder-coated galvanized-steel plenums with anodized aluminum rails and perforated diffusers |
|---|---|
| Panel de espesor | 300-420 mm overall terminal module depth including inlet base |
| Ancho efectivo | 1180-1320 mm nominal square diffuser-array width |
| Longitud máxima | Up to 1400 mm configurable square-array length |
| Acero frente a espesor | 0.8-1.2 mm powder-coated galvanized plenum sheet |
| Densidad Core | 2700 kg/m³ for anodized EN AW-6063 aluminum frame components |
| Conductividad térmica | 200-220 W/(m·K) for EN AW-6063 aluminum rails at room temperature |
| Superficie acabada | RAL 9010 epoxy powder-coated housings and perforated faces with satin natural-anodized aluminum trim |
| Tipo conjunto | Four mechanically joined terminal housings with gasketed room-side filter retainers, hinged diffusers and separate circular top inlets |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Clean Ward Supply Ceiling specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita