Siling Bekalan Ward Bersih
- Four-Module Ward Array
- Room-Side Filter Access
- Perforated Mixing Diffusers
- Independent Top Duct Inlets
Pengenalan Produk
The clean ward supply ceiling combines four independent terminal filter housings in a compact square 2-by-2 array for hospital ward bed zones and other healthcare rooms requiring filtered ceiling supply. Each shallow powder-coated steel plenum has its own top circular duct collar, retained H14 HEPA cartridge and perforated room-side diffuser. Natural-anodized aluminum rails join the modules beneath one continuous perimeter trim, while corner suspension lugs support coordinated installation above the finished ceiling. The arrangement provides broad turbulent-mixing supply without the lighting, surgical-lamp opening or large central compensation device used on an operating-room canopy.
Ciri-ciri Utama
Hinged perforated diffuser panels provide clean-side access to the filter retaining rails, seal interfaces and test points.
A separate circular inlet above each plenum reduces dependence on one deep common box and supports branch balancing.
Powder-coated exposed faces, slim anodized rails and concealed grille fasteners create wipeable room-side surfaces.
Kebimbangan Produk Pelanggan
A ward supply terminal must deliver clean air across the occupied bed zone while fitting limited ceiling space and remaining serviceable without dismantling the complete array.
Permohonan yang biasa
Parameter teknikal
Typical configurable construction values for a compact four-module clean ward supply ceiling are listed below.
| Bahan Teras | Four H14 mini-pleat HEPA cartridges in RAL 9010 powder-coated galvanized-steel plenums with anodized aluminum rails and perforated diffusers |
|---|---|
| Ketebalan Panel | 300-420 mm overall terminal module depth including inlet base |
| Lebar berkesan | 1180-1320 mm nominal square diffuser-array width |
| Panjang maksimum | Up to 1400 mm configurable square-array length |
| Keluli Menghadapi Ketebalan | 0.8-1.2 mm powder-coated galvanized plenum sheet |
| Ketumpatan teras | 2700 kg/m³ for anodized EN AW-6063 aluminum frame components |
| Kekonduksian Terma | 200-220 W/(m·K) for EN AW-6063 aluminum rails at room temperature |
| Kemasan permukaan | RAL 9010 epoxy powder-coated housings and perforated faces with satin natural-anodized aluminum trim |
| Jenis Bersatu | Four mechanically joined terminal housings with gasketed room-side filter retainers, hinged diffusers and separate circular top inlets |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Clean Ward Supply Ceiling specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)