A compact square ward air-supply ceiling built from four individually serviceable HEPA terminal modules with perforated room-side diffusers.
  • Four-Module Ward Array
  • Room-Side Filter Access
  • Perforated Mixing Diffusers
  • Independent Top Duct Inlets
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The clean ward supply ceiling combines four independent terminal filter housings in a compact square 2-by-2 array for hospital ward bed zones and other healthcare rooms requiring filtered ceiling supply. Each shallow powder-coated steel plenum has its own top circular duct collar, retained H14 HEPA cartridge and perforated room-side diffuser. Natural-anodized aluminum rails join the modules beneath one continuous perimeter trim, while corner suspension lugs support coordinated installation above the finished ceiling. The arrangement provides broad turbulent-mixing supply without the lighting, surgical-lamp opening or large central compensation device used on an operating-room canopy.

Các tính năng chính

Four individually ducted terminal modules distribute filtered air across a compact square ward ceiling footprint.

Hinged perforated diffuser panels provide clean-side access to the filter retaining rails, seal interfaces and test points.

A separate circular inlet above each plenum reduces dependence on one deep common box and supports branch balancing.

Powder-coated exposed faces, slim anodized rails and concealed grille fasteners create wipeable room-side surfaces.

Các mối quan tâm về sản phẩm của khách hàng

A ward supply terminal must deliver clean air across the occupied bed zone while fitting limited ceiling space and remaining serviceable without dismantling the complete array.

A single small ceiling outlet can create a concentrated jet while leaving weak circulation around the patient zone.Four perforated diffuser faces spread supply over a broader square area and add terminal resistance for more even room mixing.
Ceiling-side filter replacement may disturb services above the ward and require removal of finished ceiling components.Each hinged room-side diffuser exposes one retained HEPA cartridge so an individual module can be accessed below the ceiling.
Shared plenums can make branch balancing and fault isolation difficult when several filter faces serve one bed zone.Four dedicated top inlet collars allow the corresponding terminals to be connected and balanced as defined branches.
A bulky surgical canopy can consume unnecessary ceiling space and introduce lighting or equipment interfaces that a clean ward does not need.The compact four-module layout omits surgical-light openings and integrated luminaires while retaining filtered ward supply coverage.

Các ứng dụng điển hình

Hematology and protective-environment patient roomsBurn-care clean wardsTransplant recovery roomsClean intensive-care bed zones

Thông số kỹ thuật

Typical configurable construction values for a compact four-module clean ward supply ceiling are listed below.

Vật liệu lõiFour H14 mini-pleat HEPA cartridges in RAL 9010 powder-coated galvanized-steel plenums with anodized aluminum rails and perforated diffusers
Độ dày bảng điều khiển300-420 mm overall terminal module depth including inlet base
Chiều rộng hiệu quả1180-1320 mm nominal square diffuser-array width
Chiều dài tối đaUp to 1400 mm configurable square-array length
Thép đối mặt với độ dày0.8-1.2 mm powder-coated galvanized plenum sheet
Mật độ lõi2700 kg/m³ for anodized EN AW-6063 aluminum frame components
Độ dẫn nhiệt200-220 W/(m·K) for EN AW-6063 aluminum rails at room temperature
Kết thúc bề mặtRAL 9010 epoxy powder-coated housings and perforated faces with satin natural-anodized aluminum trim
Loại khớp nốiFour mechanically joined terminal housings with gasketed room-side filter retainers, hinged diffusers and separate circular top inlets
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Dry-gasket or gel-seal terminal filter retentionTop circular inlet diameters selected for branch airflowGalvanized-steel or AISI 304 stainless housing constructionFixed perforated or hinged room-side diffuser panels