The negative-pressure HEPA filtration unit places the prefilter and HEPA cassette upstream of a variable-speed centrifugal blower. Contaminated room air enters the guarded intake, is filtered under negative pressure and then exits through a round exhaust collar for connection outside the contained space or to an approved return path. A differential gauge indicates filter resistance, and gasketed access panels maintain the dirty-side pressure boundary. When operated without an exhaust duct, the same unit functions as a recirculating air scrubber but does not create room negative pressure.
Основные характеристики
A sealed round outlet accepts flexible ducting for controlled exhaust from the contained room.
Variable blower speed supports pressure adjustment as room leakage and filter resistance change.
Separate coarse and intermediate filters protect the HEPA stage during high-dust work.
Обеспокоенность клиентов продуктами
Containment requires more than HEPA recirculation: the filtered airflow must leave the room through a controlled path at a rate greater than incoming leakage.
Типичные приложения
Технические параметры
Representative construction ranges for a portable negative-pressure HEPA filtration unit are listed below.
| Основной материал | Variable-speed centrifugal blower with coarse prefilter, intermediate stage and upstream micro-glass H13-H14 HEPA filter |
|---|---|
| Толщина панели | 500-900 mm enclosure depth |
| эффективная ширина | 500-900 mm cabinet width |
| Максимальная длина | Up to 1300 mm overall unit height or longest cabinet dimension |
| Толщина линий стали | 1.0-1.5 mm dark-blue powder-coated steel or lightweight aluminium enclosure |
| Плотность ядра | Approximately 90-120 kg/m³ compacted density of the HEPA pack used in the negative-pressure filtration cabinet |
| Теплопроводимость | Approximately 0.035-0.043 W/(m·K) for the HEPA pack used in the negative-pressure exhaust path |
| Поверхностная отделка | Dark-blue chemical-resistant powder coat with black intake grille and stainless corner hardware |
| Объединенный тип | Gasketed negative-side filter door with positive-lock cassettes and sealed round exhaust duct flange |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a Negative-Pressure HEPA Filtration Unit specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

English
Немецкий
Арабский язык
Французский
Индонезийский
Японский язык
Корейский
Японский
Португальский
Русский языкТекущий
Испанский язык
Тайский
Турецкий
Вьетнамский язык