A medium-to-large liquid chiller using twin-rotor screw compression for robust continuous-duty cooling and smooth capacity control.
  • Twin-Rotor Screw Compression
  • Continuous Capacity Control
  • High-Capacity Cooling
  • Air- or Water-Cooled Options
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The screw compressor chiller uses meshing helical rotors to compress refrigerant continuously, providing fewer capacity pulses than reciprocating machinery and reliable operation at medium and large duty. Slide-valve or variable-speed control follows changing chilled-water load, while an economizer can improve capacity at favorable operating conditions. The compressor can be paired with air-cooled condenser coils or a water-cooled shell-and-tube condenser. Oil management, discharge temperature and evaporator flow are supervised by the unit controller.

Ciri-ciri Utama

Continuous rotary compression is suited to long operating hours and medium-to-large cooling loads.

Slide-valve or variable-speed modulation adjusts capacity without relying only on start-stop cycling.

Economizer and liquid-injection options can support capacity and compressor temperature control.

Air-cooled and water-cooled arrangements allow the compressor platform to match the available heat sink.

Kebimbangan Produk Pelanggan

Screw chillers perform best when oil management, minimum load, water flow and condensing conditions remain within the compressor operating envelope.

Low plant load forces frequent compressor starts.Variable capacity and correctly sized system volume maintain longer stable operating cycles.
Oil remains in the evaporator during prolonged low-load operation.Oil separation, return control and minimum refrigerant velocity protect compressor lubrication.
Sudden process load changes cause chilled-water temperature excursions.Fast capacity modulation and leaving-water control respond without waiting for another compressor stage.
High discharge temperature limits operation at extreme conditions.Economizer, liquid injection or appropriate condensing control keeps the compressor within its map.

Permohonan yang biasa

Large cleanroom HVAC plantsSemiconductor process coolingPharmaceutical central utilitiesData and electronics facilitiesIndustrial chilled-water production

Parameter teknikal

Typical enclosure and compressor acoustic-lining data for a screw chiller are shown below.

Bahan TerasSemi-rigid glass-fibre board inside the compressor acoustic enclosure
Ketebalan Panel1.2–2.0 mm removable compressor enclosure panels
Lebar berkesan1400–3000 mm nominal equipment width
Panjang maksimumUp to 12000 mm for air-cooled or 7500 mm for water-cooled configuration
Keluli Menghadapi Ketebalan1.2–2.5 mm coated steel frame and service enclosure
Ketumpatan teras48 kg/m³ semi-rigid glass-fibre acoustic board
Kekonduksian Terma0.033 W/(m·K) at 25°C for the glass-fibre board
Kemasan permukaanPowder-coated structural steel and removable weather-resistant or indoor service panels
Jenis BersatuWelded equipment skid with bolted acoustic panels and flanged or grooved water connections
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Fixed-speed slide-valve or variable-speed compressorAir-cooled or water-cooled condenserEconomizer, heat recovery and free coolingStandard, low-noise or ultra-low-noise package

Planning a Screw Compressor Chiller specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami