Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

Screw Compresseur à vis refroidissement

A medium-to-large liquid chiller using twin-rotor screw compression for robust continuous-duty cooling and smooth capacity control.
  • Twin-Rotor Screw Compression
  • Continuous Capacity Control
  • High-Capacity Cooling
  • Air- or Water-Cooled Options
Demander un devis. Browse les produits

Introduction de produit

The screw compressor chiller uses meshing helical rotors to compress refrigerant continuously, providing fewer capacity pulses than reciprocating machinery and reliable operation at medium and large duty. Slide-valve or variable-speed control follows changing chilled-water load, while an economizer can improve capacity at favorable operating conditions. The compressor can be paired with air-cooled condenser coils or a water-cooled shell-and-tube condenser. Oil management, discharge temperature and evaporator flow are supervised by the unit controller.

Key Features

Continuous rotary compression is suited to long operating hours and medium-to-large cooling loads.

Slide-valve or variable-speed modulation adjusts capacity without relying only on start-stop cycling.

Economizer and liquid-injection options can support capacity and compressor temperature control.

Air-cooled and water-cooled arrangements allow the compressor platform to match the available heat sink.

Préoccupations du client produit

Screw chillers perform best when oil management, minimum load, water flow and condensing conditions remain within the compressor operating envelope.

Low plant load forces frequent compressor starts.Variable capacity and correctly sized system volume maintain longer stable operating cycles.
Oil remains in the evaporator during prolonged low-load operation.Oil separation, return control and minimum refrigerant velocity protect compressor lubrication.
Sudden process load changes cause chilled-water temperature excursions.Fast capacity modulation and leaving-water control respond without waiting for another compressor stage.
High discharge temperature limits operation at extreme conditions.Economizer, liquid injection or appropriate condensing control keeps the compressor within its map.

Les applications typiques

Large cleanroom HVAC plantsSemiconductor process coolingPharmaceutical central utilitiesData and electronics facilitiesIndustrial chilled-water production

Paramètres techniques

Typical enclosure and compressor acoustic-lining data for a screw chiller are shown below.

Matériaux de baseSemi-rigid glass-fibre board inside the compressor acoustic enclosure
Panneau épaisseur1.2–2.0 mm removable compressor enclosure panels
Largeur effective1400–3000 mm nominal equipment width
Longueur maximaleUp to 12000 mm for air-cooled or 7500 mm for water-cooled configuration
Acier face épaisseur1.2–2.5 mm coated steel frame and service enclosure
Densité Core48 kg/m³ semi-rigid glass-fibre acoustic board
Conductivité thermique0.033 W/(m·K) at 25°C for the glass-fibre board
surface finiePowder-coated structural steel and removable weather-resistant or indoor service panels
Type jointWelded equipment skid with bolted acoustic panels and flanged or grooved water connections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Fixed-speed slide-valve or variable-speed compressorAir-cooled or water-cooled condenserEconomizer, heat recovery and free coolingStandard, low-noise or ultra-low-noise package

Planning a Screw Compressor Chiller specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil