Unit Dehumidification Udara Segar
- 100 Percent Outdoor-Air Treatment
- Cooling Plus Desiccant Drying
- Recovered Condenser Heat
- Cleanroom Pressure Support
Pengenalan Produk
The fresh-air dehumidification unit treats the ventilation and replacement air that creates the largest seasonal latent load in many cleanrooms. A prefilter and cooling coil remove heat and bulk moisture, the desiccant section lowers the dew point, and recovered condenser or reactivation heat tempers the leaving air. Weather-resistant louvers, drainable coil sections and pressure-capable fans allow the unit to supply dry make-up air without burdening the recirculation AHU.
Ciri-ciri Utama
Mechanical cooling handles high-temperature bulk condensation while the desiccant stage addresses the remaining vapor load.
Recovered refrigeration heat can temper overcooled air and reduce separate reheat energy.
Low-leakage dampers and variable-speed supply control maintain the scheduled make-up airflow as filters load.
Kebimbangan Produk Pelanggan
Untreated outdoor air can overwhelm the sensible and latent capacity of a cleanroom recirculation unit, especially during humid weather.
Permohonan yang biasa
Parameter teknikal
Typical casing and dimensional ranges for a packaged cleanroom fresh-air dehumidification unit are shown below.
| Bahan Teras | Cooling coil and desiccant rotor in a mineral-wool-insulated galvanized steel air-handling casing |
|---|---|
| Ketebalan Panel | 40-60 mm double-skin insulated casing panel thickness |
| Lebar berkesan | 1200-3500 mm nominal outdoor-air unit width |
| Panjang maksimum | Up to 7500 mm including intake filtration cooling rotor and supply-fan sections |
| Keluli Menghadapi Ketebalan | 0.8-1.2 mm pre-painted outer skin and galvanized or stainless inner skin |
| Ketumpatan teras | 45-80 kg/m³ typical mineral-wool casing insulation density |
| Kekonduksian Terma | Approximately 0.035-0.045 W/(m·K) for mineral-wool casing insulation |
| Kemasan permukaan | White weather-resistant powder coating with light-blue service doors and stainless wet-section surfaces |
| Jenis Bersatu | Bolted gasketed casing modules with flanged duct openings, flexible fan connections and welded drain pan |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Fresh-Air Dehumidification Unit specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki