A packaged outdoor-air unit that filters, cools, dries and tempers humid make-up air before it enters a cleanroom air-handling or pressure-control system.
  • 100 Percent Outdoor-Air Treatment
  • Cooling Plus Desiccant Drying
  • Recovered Condenser Heat
  • Cleanroom Pressure Support
見積もりリクエスト 製品案内

商品紹介

The fresh-air dehumidification unit treats the ventilation and replacement air that creates the largest seasonal latent load in many cleanrooms. A prefilter and cooling coil remove heat and bulk moisture, the desiccant section lowers the dew point, and recovered condenser or reactivation heat tempers the leaving air. Weather-resistant louvers, drainable coil sections and pressure-capable fans allow the unit to supply dry make-up air without burdening the recirculation AHU.

主要な特徴

A full outdoor-air intake path isolates ventilation moisture before it reaches the cleanroom recirculation system.

Mechanical cooling handles high-temperature bulk condensation while the desiccant stage addresses the remaining vapor load.

Recovered refrigeration heat can temper overcooled air and reduce separate reheat energy.

Low-leakage dampers and variable-speed supply control maintain the scheduled make-up airflow as filters load.

お客様の製品に関する懸念事項

Untreated outdoor air can overwhelm the sensible and latent capacity of a cleanroom recirculation unit, especially during humid weather.

Summer ventilation air drives room humidity above the process limit despite adequate recirculation cooling.The dedicated unit removes outdoor latent load before the make-up air joins the cleanroom supply stream.
Deep cooling alone produces air that is dry enough but too cold for direct delivery.Recovered condenser heat or a controlled heating coil resets the dry air to the required supply temperature.
A dirty intake filter reduces make-up airflow and weakens cleanroom positive pressure.Differential-pressure monitoring and variable-speed fan control preserve scheduled airflow and signal filter service.
Rain and wind-driven moisture enter through an exposed outside-air opening.A weather louver, drainable intake plenum and sloped stainless drain pan separate liquid water before the treatment sections.

典型的な用途

Positive-pressure pharmaceutical cleanroomsLaboratory ventilation make-up airMedical-device manufacturing suitesElectronics plants in humid climatesClean corridors serving process exhaust rooms

技術的なパラメータ

Typical casing and dimensional ranges for a packaged cleanroom fresh-air dehumidification unit are shown below.

コア材料Cooling coil and desiccant rotor in a mineral-wool-insulated galvanized steel air-handling casing
パネルの厚さ40-60 mm double-skin insulated casing panel thickness
有効幅1200-3500 mm nominal outdoor-air unit width
最大長さUp to 7500 mm including intake filtration cooling rotor and supply-fan sections
鋼鉄の厚さを直面する0.8-1.2 mm pre-painted outer skin and galvanized or stainless inner skin
コア密度45-80 kg/m³ typical mineral-wool casing insulation density
熱伝導率Approximately 0.035-0.045 W/(m·K) for mineral-wool casing insulation
表面仕上げWhite weather-resistant powder coating with light-blue service doors and stainless wet-section surfaces
ジョイントタイプBolted gasketed casing modules with flanged duct openings, flexible fan connections and welded drain pan
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Direct-expansion or chilled-water cooling sectionDesiccant wheel with electric steam or gas reactivationMERV 8 prefilter through high-efficiency final filter stagesOutdoor roof curb, weather hood and remote building-network controls