Unité de déshumidification à air frais

A packaged outdoor-air unit that filters, cools, dries and tempers humid make-up air before it enters a cleanroom air-handling or pressure-control system.
  • 100 Percent Outdoor-Air Treatment
  • Cooling Plus Desiccant Drying
  • Recovered Condenser Heat
  • Cleanroom Pressure Support
Demander un devis. Browse les produits

Introduction de produit

The fresh-air dehumidification unit treats the ventilation and replacement air that creates the largest seasonal latent load in many cleanrooms. A prefilter and cooling coil remove heat and bulk moisture, the desiccant section lowers the dew point, and recovered condenser or reactivation heat tempers the leaving air. Weather-resistant louvers, drainable coil sections and pressure-capable fans allow the unit to supply dry make-up air without burdening the recirculation AHU.

Key Features

A full outdoor-air intake path isolates ventilation moisture before it reaches the cleanroom recirculation system.

Mechanical cooling handles high-temperature bulk condensation while the desiccant stage addresses the remaining vapor load.

Recovered refrigeration heat can temper overcooled air and reduce separate reheat energy.

Low-leakage dampers and variable-speed supply control maintain the scheduled make-up airflow as filters load.

Préoccupations du client produit

Untreated outdoor air can overwhelm the sensible and latent capacity of a cleanroom recirculation unit, especially during humid weather.

Summer ventilation air drives room humidity above the process limit despite adequate recirculation cooling.The dedicated unit removes outdoor latent load before the make-up air joins the cleanroom supply stream.
Deep cooling alone produces air that is dry enough but too cold for direct delivery.Recovered condenser heat or a controlled heating coil resets the dry air to the required supply temperature.
A dirty intake filter reduces make-up airflow and weakens cleanroom positive pressure.Differential-pressure monitoring and variable-speed fan control preserve scheduled airflow and signal filter service.
Rain and wind-driven moisture enter through an exposed outside-air opening.A weather louver, drainable intake plenum and sloped stainless drain pan separate liquid water before the treatment sections.

Les applications typiques

Positive-pressure pharmaceutical cleanroomsLaboratory ventilation make-up airMedical-device manufacturing suitesElectronics plants in humid climatesClean corridors serving process exhaust rooms

Paramètres techniques

Typical casing and dimensional ranges for a packaged cleanroom fresh-air dehumidification unit are shown below.

Matériaux de baseCooling coil and desiccant rotor in a mineral-wool-insulated galvanized steel air-handling casing
Panneau épaisseur40-60 mm double-skin insulated casing panel thickness
Largeur effective1200-3500 mm nominal outdoor-air unit width
Longueur maximaleUp to 7500 mm including intake filtration cooling rotor and supply-fan sections
Acier face épaisseur0.8-1.2 mm pre-painted outer skin and galvanized or stainless inner skin
Densité Core45-80 kg/m³ typical mineral-wool casing insulation density
Conductivité thermiqueApproximately 0.035-0.045 W/(m·K) for mineral-wool casing insulation
surface finieWhite weather-resistant powder coating with light-blue service doors and stainless wet-section surfaces
Type jointBolted gasketed casing modules with flanged duct openings, flexible fan connections and welded drain pan
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Direct-expansion or chilled-water cooling sectionDesiccant wheel with electric steam or gas reactivationMERV 8 prefilter through high-efficiency final filter stagesOutdoor roof curb, weather hood and remote building-network controls

Planning a Fresh-Air Dehumidification Unit specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.