Meter Bioluminescence ATP

A handheld luminometer that rapidly measures ATP test-device light output for objective verification of surface-cleaning effectiveness.
  • Rapid RLU Measurement
  • Large Touchscreen Workflow
  • Removable Read Chamber
  • Wireless Data Transfer
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The ATP Bioluminescence Meter detects light produced when an activated ATP test reacts with biological residue. A shielded read chamber and sensitive photodiode convert emitted light into relative light units, while guided touchscreen workflows associate results with locations, users and limits. Rechargeable portable operation and digital synchronization support immediate hygiene decisions at the sampling point.

Ciri-ciri Utama

Sensitive photodiode detection measures low-level bioluminescent signals in seconds.

A guided touchscreen reduces entry errors across locations and test plans.

The removable read chamber allows accessible cleaning after accidental test-device leakage.

Onboard storage and wireless or USB connectivity simplify trend reporting.

Kebimbangan Produk Pelanggan

Rapid hygiene verification must deliver a consistent quantitative result while preventing chamber contamination and transcription errors.

Visual inspection cannot detect invisible organic residue.ATP bioluminescence converts residual biological material into an objective RLU result.
Manual recording causes location and result transcription mistakes.Programmed locations, users and test plans bind metadata directly to each reading.
A leaking test device contaminates the optical chamber.A removable cleanable chamber insert isolates and protects the detector area.
Delayed reporting slows corrective cleaning decisions.Rapid measurement and wireless synchronization make results available at the point of use.

Permohonan yang biasa

Cleanroom surface hygiene verificationEquipment cleaning checksSanitation program trendingRapid process-area screening

Parameter teknikal

Typical construction values for a handheld ATP bioluminescence meter are listed below.

Bahan TerasImpact-resistant polymer housing with photodiode optical read chamber
Ketebalan Panel2-4 mm nominal housing wall
Lebar berkesan80-90 mm handheld instrument width
Panjang maksimumUp to 270 mm overall instrument length
Keluli Menghadapi Ketebalan0.8-1.2 mm equivalent internal shield thickness
Ketumpatan teras1050-1200 kg/m³ for engineered polymer housing
Kekonduksian Terma0.18-0.30 W/(m·K) for housing polymer
Kemasan permukaanTextured blue-gray grip with shatter-resistant color touchscreen
Jenis BersatuHinged or removable test-chamber cover with replaceable optical insert
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Surface or water ATP testsCharging dockWi-Fi and USB data transferProtective carrying case