Peranti Pengukuran Aliran Injap Udara
- Full-flow capture at circular air valves.
- Integrated straightener controls swirl effects.
- Compact bidirectional direct-flow display.
Pengenalan Produk
This device seals a shaped low-resistance cone around a circular air valve and guides the full stream through an integrated flow straightener and sensing grid. The detachable digital meter displays supply or extract volume flow without requiring a separate area calculation. Its compact mouth is easier to position on small ceiling and wall terminals than a full-size capture hood.
Ciri-ciri Utama
Integrated straightener reduces swirl-related measurement variation.
Reversible sensing supports supply and extract terminals.
Direct volume-flow display removes manual area conversion.
Soft perimeter seal limits bypass around the valve face.
Compact handheld format suits congested ceiling locations.
Kebimbangan Produk Pelanggan
Circular air valves generate curved and swirling flow patterns that are difficult to quantify with a point sensor and often sit where a full-size hood cannot be positioned.
Permohonan yang biasa
Parameter teknikal
Representative compact valve-flow device dimensions are listed below; cone diameter, handle reach and measurement range can be selected for terminal size.
| Bahan Teras | Molded engineering-polymer cone, elastomer perimeter seal and differential-pressure sensing grid |
|---|---|
| Ketebalan Panel | Typically 2.5-4.0 mm for the molded cone wall |
| Lebar berkesan | Approximately 250-350 mm across the capture mouth |
| Panjang maksimum | Approximately 400-550 mm including handle and display |
| Keluli Menghadapi Ketebalan | Typically 0.5-0.8 mm for stainless sensing-grid elements |
| Ketumpatan teras | Approximately 1050-1200 kg/m³ for the engineered polymer cone |
| Kekonduksian Terma | Approximately 0.18-0.25 W/(m·K) for the engineered polymer housing |
| Kemasan permukaan | Matte white capture cone with graphite handle, black seal and blue-gray display |
| Jenis Bersatu | Detachable meter coupling with sealed cone-to-grid interface and soft valve-face gasket |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Air Valve Flow Measurement Device specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)