Dispositif de mesure de débit de valve d'air par
- Full-flow capture at circular air valves.
- Integrated straightener controls swirl effects.
- Compact bidirectional direct-flow display.
Introduction de produit
This device seals a shaped low-resistance cone around a circular air valve and guides the full stream through an integrated flow straightener and sensing grid. The detachable digital meter displays supply or extract volume flow without requiring a separate area calculation. Its compact mouth is easier to position on small ceiling and wall terminals than a full-size capture hood.
Key Features
Integrated straightener reduces swirl-related measurement variation.
Reversible sensing supports supply and extract terminals.
Direct volume-flow display removes manual area conversion.
Soft perimeter seal limits bypass around the valve face.
Compact handheld format suits congested ceiling locations.
Préoccupations du client produit
Circular air valves generate curved and swirling flow patterns that are difficult to quantify with a point sensor and often sit where a full-size hood cannot be positioned.
Les applications typiques
Paramètres techniques
Representative compact valve-flow device dimensions are listed below; cone diameter, handle reach and measurement range can be selected for terminal size.
| Matériaux de base | Molded engineering-polymer cone, elastomer perimeter seal and differential-pressure sensing grid |
|---|---|
| Panneau épaisseur | Typically 2.5-4.0 mm for the molded cone wall |
| Largeur effective | Approximately 250-350 mm across the capture mouth |
| Longueur maximale | Approximately 400-550 mm including handle and display |
| Acier face épaisseur | Typically 0.5-0.8 mm for stainless sensing-grid elements |
| Densité Core | Approximately 1050-1200 kg/m³ for the engineered polymer cone |
| Conductivité thermique | Approximately 0.18-0.25 W/(m·K) for the engineered polymer housing |
| surface finie | Matte white capture cone with graphite handle, black seal and blue-gray display |
| Type joint | Detachable meter coupling with sealed cone-to-grid interface and soft valve-face gasket |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Air Valve Flow Measurement Device specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien