クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム管理 · 環境モニタリングシステム

リモート警報モジュール

A distributed I/O module that collects local alarm contacts, drives remote indicators and reports point status to a cleanroom central alarm or monitoring system.
  • Isolated Alarm Inputs
  • Configurable Relay Outputs
  • Local Point LEDs
  • Networked Distributed I/O
見積もりリクエスト 製品案内

商品紹介

The remote alarm module places alarm acquisition close to cleanroom equipment, sensors or utility panels. Isolated digital inputs receive dry contacts or selected voltage states, and local LEDs show channel condition during service. Relay outputs can operate beacons, sounders or shutdown interlocks under central or local logic. RS-485 or Ethernet communication transfers point status, channel diagnostics and output commands to the central system, reducing long individual cable runs from every alarm point.

主要な特徴

Galvanically isolated inputs protect central electronics from field wiring disturbances.

Local channel LEDs show input and relay state without opening software tools.

Distributed placement reduces the amount of home-run alarm cable across the facility.

Watchdog and communication-fault indication distinguish a network problem from a normal input.

お客様の製品に関する懸念事項

Distributed alarm I/O must preserve channel identity and reveal communication loss rather than silently freezing the last known state.

Dozens of alarm contacts require long home-run cables to the central panel.A local module aggregates nearby points onto one supervised communication link.
Technicians cannot see whether an input is active at the field cabinet.Per-channel LEDs show physical input and commanded output states locally.
A field voltage transient damages the central alarm controller.Isolated inputs and relays separate remote wiring from the communication electronics.
Network loss leaves the operator believing all remote points are normal.Watchdog and heartbeat monitoring generate a dedicated module-offline alarm.

典型的な用途

Remote cleanroom alarm zonesUtility equipment contactsGas and leak detector outputsDoor and airlock alarm collection

技術的なパラメータ

Typical construction values for a distributed cleanroom remote alarm I/O module are listed below.

コア材料FR-4 isolated I/O board with copper relay contacts in flame-retardant polycarbonate DIN-rail housing
パネルの厚さ80-130 mm module depth
有効幅45-160 mm DIN-rail width
最大長さUp to 180 mm module height
鋼鉄の厚さを直面する0 mm; non-metallic DIN-rail enclosure
コア密度1180-1450 kg/m³ for reinforced polymer housing
熱伝導率0.19 — 0.35 W / ( m · K ) ポリマーエンクロージャ材料用
表面仕上げLight-gray DIN-rail housing with green input LEDs, red alarm LEDs and blue network label
ジョイントタイプDIN-rail clip with removable input-output terminals and RS-485 or Ethernet connector
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Digital input and relay combinationsModbus RTU or TCPLocal fail-safe logicGasketed field enclosure