A top-filtered clean bench that directs uniform HEPA-filtered air downward across non-hazardous products and the stainless work surface.
  • Top-Mounted HEPA Supply
  • Uniform Vertical Downflow (Alir Vertikal)
  • Stainless Work Surface
  • Compact Bench Depth
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The vertical clean bench places its fan-filter section above the work zone so filtered air moves from the ceiling diffuser toward the perforated or open work area. This arrangement keeps the cabinet depth compact and allows larger instruments to sit near the rear wall without blocking a rear filter face. The inner liner and work tray are formed from cleanable stainless steel, while a clear front sash helps limit room-air disturbance. It is intended for non-hazardous assembly, preparation and inspection work that requires product protection rather than personnel containment.

Fitur utama:

A full-width ceiling diffuser spreads filtered air over the complete work surface.

The top-mounted fan-filter section preserves usable rear-wall space for instruments and fixtures.

A removable stainless work tray exposes the lower collection area for cleaning.

The adjustable front sash reduces cross-drafts while retaining comfortable hand access.

A differential-pressure indicator makes filter loading visible during routine operation.

Kekhawatiran produk pelanggan

A vertical bench must maintain clean downward airflow without allowing tall equipment, room drafts or service work to compromise the protected zone.

Tall instruments create stagnant pockets beneath a small supply grille.A full-width ceiling diffuser distributes air around equipment footprints from above.
Room movement disturbs the open working face.The lowered clear sash and side panels shield the downflow while preserving access.
Spills collect beneath a fixed work surface.Lift-out stainless work sections provide direct cleaning access to the lower pan.
Operators cannot see gradual filter loading.A visible pressure gauge or electronic alarm indicates increasing resistance.

Aplikasi yang Tipis

Medical-device assemblyOptical component inspectionCulture-media preparation with non-hazardous materialsPrecision electronics handling

Parameter teknis

Typical configurable construction ranges for a vertical laminar flow clean bench are listed below.

Bahan intiSUS304 work-zone liner with a powder-coated steel outer cabinet and mineral-wool acoustic infill
Ketebalan Panel (Panel Thickness)25-40 mm double-skin cabinet sections
Efektif lebar900 - 1800 mm lebar kerja yang jelas
Panjang maksimumHingga 2200 mm ketinggian kabinet keseluruhan
Baja menghadap ketebalan0.8-1.2 mm powder-coated steel; 1.0-1.2 mm SUS304 work-zone liner
Kepadatan inti (core density)80 - 120 kg / m3 mineral-wol akustik infill
Konduktivitas Termal (Thermal Conductivity)0.035-0.045 W/(m·K) for the mineral-wool infill
Permukaan selesaiLow-sheen white powder coating outside with brushed SUS304 work surfaces
Jenis BersamaSealed double-skin cabinet seams with a removable work tray and gasketed HEPA filter frame
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

HEPA or ULPA final filterManual or motorized front sashUV-resistant clear side panelsElectrical outlets and service taps