Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Filter udara dan filtrasi kimia

Terminal HEPA Filter

A low-profile final filter engineered for direct installation in cleanroom ceiling terminals, diffuser housings and laminar-flow supply modules.
  • Ceiling-Terminal Format
  • Uniform Downward Airflow
  • Room-Side Service Option
  • Protected Mini-Pleat Pack
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The terminal HEPA filter packages a shallow mini-pleat media pack in a cleanroom-compatible anodized-aluminum frame sized for ceiling modules, fan filter units and laminar-flow diffusers. The downstream face is kept flat and protected so air can enter the occupied clean zone uniformly after the terminal screen or diffuser. A full perimeter seal interfaces with the terminal housing, and the low profile preserves plenum height above the ceiling grid. Optional scan-test and pressure-drop arrangements support routine in-place assessment without disturbing the upstream ductwork.

Fitur utama:

A shallow ceiling-module format minimizes the plenum depth required above clean spaces.

Uniform mini-pleat spacing supports even discharge across a perforated face or diffuser screen.

Anodized-aluminum perimeter framing withstands repeated room-side cleaning and filter replacement.

Selectable sealing edges match common room-side replaceable and top-loading terminal housings.

Kekhawatiran produk pelanggan

Terminal filtration must provide a final leak-resistant barrier without creating uneven supply patterns or consuming excessive ceiling plenum space.

A full-depth HEPA cell conflicts with ducts and utilities above a low ceiling.The shallow mini-pleat panel preserves clearance within crowded service plenums.
Nonuniform filter resistance creates visible high-velocity spots at the diffuser face.Consistent pleat spacing and full perimeter potting distribute flow across the complete terminal area.
Filter replacement from above interrupts utilities and exposes the plenum.A compatible room-side retaining arrangement allows the panel to be removed from the clean space.
Ceiling-grid movement compromises the seal around the final filter.A rigid aluminum frame and purpose-selected gasket, gel channel or knife edge maintain a defined sealing interface.

Aplikasi yang Tipis

Pharmaceutical cleanroom supply ceilingsHospital operating-room terminalsElectronics and semiconductor cleanroomsLaminar-flow canopiesRoom-side replaceable HEPA modules

Parameter teknis

Typical construction ranges for a cleanroom ceiling terminal HEPA filter are listed below.

Bahan intiLow-resistance microglass mini-pleat HEPA media with continuous glass-filament or thermoplastic separators
Ketebalan Panel (Panel Thickness)70, 90 or 100 mm terminal-filter depth
Efektif lebar305-610 mm ceiling-module width
Panjang maksimumUp to 1220 mm terminal panel length
Baja menghadap ketebalan0.40-0.60 mm powder-coated steel or stainless-steel downstream faceguard
Kepadatan inti (core density)Approximately 80-145 kg/m³ nominal mini-pleat pack density
Konduktivitas Termal (Thermal Conductivity)Approximately 0.033-0.039 W/(m·K) for dry low-resistance terminal-filter media
Permukaan selesaiClear anodized or white powder-coated aluminum frame with clean white media
Jenis BersamaPotted mini-pleat panel with gasket, gel channel or knife-edge perimeter matched to the terminal housing
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

H13, H14 or ULPA efficiencyRoom-side replaceable or top-loading frameGel seal, gasket seal or integral knife edgePressure-drop port and scan-test access compatibility

Planning a Terminal HEPA Filter specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami