Instruments d'essai et de validation de salle blanche

Z micromanomètre

A high-resolution dual-port micromanometer for cleanroom pressure-cascade checks, filter pressure-drop testing and Pitot-tube duct traverses.
  • High-resolution low-pressure measurement.
  • Dual ports for cleanroom cascade verification.
  • Pitot velocity and volume-flow calculation.
Demander un devis. Browse les produits

Introduction de produit

This portable micromanometer resolves small static and differential air pressures through two color-coded pressure ports. Automatic zeroing, selectable engineering units and damping help stabilize readings at airlocks and controlled rooms. With a Pitot tube and entered duct geometry, the same instrument can calculate velocity and air volume during ventilation commissioning.

Key Features

Sensitive differential-pressure sensor resolves small room-pressure changes.

Dual ports support positive, negative and differential measurements.

Selectable damping steadies readings affected by door movement or turbulence.

Pitot input converts velocity pressure into duct air speed and flow.

Min, max and average capture supports systematic test-point review.

Rugged handheld enclosure suits qualification and maintenance routes.

Préoccupations du client produit

Controlled environments depend on small pressure differences that must be measured without confusing transient fluctuations, tubing polarity or instrument drift.

Small room-pressure differentials can be obscured by sensor noise.A high-resolution low-pressure sensor with damping produces a stable displayed value.
Reversed tubing can make pressure direction difficult to interpret.Color-coded positive and negative ports make the connection polarity immediately visible.
Door movement creates short transients during cascade checks.Averaging and min/max capture distinguish the settled relationship from brief disturbances.
Duct velocity calculations add time and opportunities for arithmetic errors.Pitot mode and entered duct dimensions provide direct velocity and volume-flow results.

Les applications typiques

Cleanroom pressure-cascade verificationAirlock and isolation-room testingHEPA filter pressure-drop measurementPitot-tube duct traversesHVAC commissioning and balancing

Paramètres techniques

Typical portable micromanometer construction is summarized below; pressure range, damping, logging and probe accessories can be matched to the qualification method.

Matériaux de basePiezoresistive pressure sensor, brass pressure ports and impact-resistant polymer enclosure
Panneau épaisseurTypically 2.0-3.5 mm for the molded instrument housing
Largeur effectiveApproximately 75-100 mm across the handheld meter body
Longueur maximaleApproximately 180-230 mm for the handheld instrument body
Acier face épaisseurTypically 0.5-1.0 mm for optional stainless Pitot and static-pressure probes
Densité CoreApproximately 1050-1200 kg/m³ for the engineered polymer enclosure
Conductivité thermiqueApproximately 0.18-0.25 W/(m·K) for the engineered polymer enclosure
surface finieDark graphite overmolded housing with blue and red pressure-port identifiers
Type jointBarbed dual pressure ports for flexible tubing with keyed accessory interfaces
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Low- or extended-pressure rangePitot tube setStatic-pressure probesFlexible tubing kitData-logging configurationProtective carrying case

Planning a Micromanometer specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat