Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Sistemas de distribución de aire para salas limpias

Puerta de acceso aislada

A gasketed double-wall access door that provides repeatable entry for inspection, cleaning and servicing inside rectangular HVAC ducts.
  • Double-Wall Insulated Panel
  • Compression Cam Latches
  • Continuous Perimeter Gasket
  • Hinged or Lift-Off Design
Solicite un presupuesto. Browse productos

Introducción del producto

The insulated duct access door mounts into a prepared rectangular opening and provides a rigid, reusable closure for internal inspection. A double-wall metal panel surrounds a non-shedding insulation core, while a continuous closed-cell gasket seals against the frame. Cam latches apply even compression and a piano hinge retains the door in overhead or vertical service positions. The frame edge is hemmed or flanged into the duct wall and sealed externally so cleaning liquids and air do not bypass the opening.

Características clave

Double-wall construction limits thermal bridging through insulated supply and return ductwork.

Adjustable cam latches apply repeatable gasket compression after each inspection cycle.

A continuous closed-cell perimeter seal avoids open corners around the access opening.

Hinged and lift-off formats suit overhead, side-wall and restricted-service locations.

Preocupaciones del producto del cliente

An access opening must be large enough for the intended task yet close with the same thermal and leakage integrity as the surrounding duct wall.

A cut sheet-metal cover distorts after repeated removal.A reinforced double-wall door and fixed frame preserve alignment through service cycles.
Warm humid air condenses on a single-skin access panel.Enclosed insulation reduces the temperature difference across the closure.
Uneven screw tightening leaves gaps along the gasket.Multiple cam latches distribute compression around the full perimeter.
Loose insulation fibers are exposed at the door edge.Metal skins and hemmed frame edges completely enclose the insulation core.

Aplicaciones típicas

Filter and damper inspectionCoil and humidifier accessDuct cleaning entry pointsFire and smoke damper serviceCleanroom exhaust inspection

Parámetros técnicos

Representative construction ranges for an insulated rectangular duct access door are shown below.

Materiales CoreClosed-cell elastomeric foam or non-shedding fiberglass insulation enclosed by metal skins
Panel de espesor25–50 mm double-wall door depth
Ancho efectivo150–650 mm clear opening width
Longitud máxima450 mm standard opening height; up to 650 mm by custom fabrication
Acero frente a espesor0.7–1.0 mm galvanized steel or 304 stainless steel skins
Densidad Core32–48 kg/m³ enclosed insulation core
Conductividad térmica0.034–0.040 W/(m·K) for the insulated core
Superficie acabadaGalvanized, powder-coated or brushed stainless steel with closed-cell gasket
Tipo conjuntoHinged or lift-off frame with continuous gasket and adjustable cam latches
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Galvanized or 304 stainless constructionHinged or lift-off doorRound-duct saddle frameTool-operated or hand cam latches

Planning a Insulated Duct Access Door specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto