Analizador de humedad de aire comprimido
- Direct compressed-air water-vapour analysis.
- Regulated pressure and visible sample flow.
- Low-dead-volume conditioned sampling path.
Introducción del producto
This analyzer routes a small representative compressed-air sample through a dedicated conditioning path before it reaches the moisture sensor. A pressure regulator, vertical flowmeter and transparent condensate-protection bowl help establish controlled inlet conditions and reveal an unsuitable wet sample before liquid reaches the measurement cell. Short stainless-steel and PTFE wetted paths reduce dead volume and ambient-moisture ingress, while the front display supports water-vapour trending in ppm(v) or dew-point units. Because line pressure affects the interpretation of dew point, the selected pressure basis, sample location and flow condition should be recorded with every result.
Características clave
Single front pressure regulator and vertical flowmeter make the conditioned side-stream settings easy to reproduce.
Transparent sample-treatment bowl provides a visible barrier against entrained liquid and particulate contamination.
Low-dead-volume stainless-steel and PTFE sample paths limit slow dry-down and moisture released from unsuitable tubing.
Separate compressed-air inlet and controlled outlet preserve a clear flow direction through the sensing cell.
Compact four-foot enclosure supports stable bench use while a recessed top handle allows protected field transport.
Preocupaciones del producto del cliente
Trace-moisture results can be dominated by leaks, tubing diffusion, retained water, pressure changes and an unrepresentative sampling point, so the complete sample path must be treated as part of the measurement.
Aplicaciones típicas
Parámetros técnicos
Representative construction for a compact compressed-air moisture analyzer is listed below; sensor technology, pressure reduction, measurement units and sample-line materials should be selected for the expected moisture level and reporting basis.
| Materiales Core | PC/ABS and powder-coated aluminum instrument enclosure with 316L stainless-steel wetted fittings, borosilicate flow tube, transparent polycarbonate conditioning bowl, PTFE sample tubing and a ceramic metal-oxide or capacitive moisture-sensor module |
|---|---|
| Panel de espesor | Typically 1.5-2.5 mm for the enclosure shell and internal instrument mounting panel |
| Ancho efectivo | Approximately 300-360 mm across the bench-top control enclosure |
| Longitud máxima | Approximately 360-430 mm for the complete enclosure, excluding the detachable sample tube |
| Acero frente a espesor | Typically 0.8-1.2 mm for internal shielding, sensor brackets and sample-conditioning retainers |
| Densidad Core | Approximately 1100-1200 kg/m³ for the PC/ABS enclosure components |
| Conductividad térmica | Approximately 0.19-0.22 W/(m·K) for the PC/ABS enclosure components |
| Superficie acabada | Warm light-gray fine-texture enclosure, cobalt-blue display bezel and handle, dark-gray controls, clear conditioning components and satin stainless-steel sample fittings |
| Tipo conjunto | Two directional compression-sealed compressed-air connections with a panel regulator, needle-controlled variable-area flowmeter, removable conditioning bowl and low-diffusion PTFE sample tube |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Compressed Air Moisture Analyzer specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita