Inicio / Productos / Productos ESD y Antistáticos / Cleanroom ESD Grounding System
Productos ESD y Antistáticos

Sistema de puesta a tierra ESD para sala limpia

The Cleanroom ESD Grounding System is a coordinated common-point network for bonding benches, mats, personnel connections and approved equipment to a verified protective earth.
  • Central common-point hub brings work surfaces, operators and compatible equipment to the same reference potential.
  • Clearly identified leads and locking connectors simplify installation, inspection and fault tracing.
  • Optional continuous monitoring provides immediate visual and audible warning of a broken ground path.
Solicite un presupuesto. Browse productos

Introducción del producto

The system centers on a wall- or bench-mounted metal common-point hub with individually identified terminals. A green-and-yellow protective-earth lead connects the hub to a verified facility ground. Separate cords serve work surfaces, floor elements and personnel connection blocks so each path can be inspected without daisy chaining. An optional monitor supervises selected conductors and reports open or high-resistance conditions through status lamps and an audible alarm.

Características clave

Star-topology common point avoids series-connected workstation elements.

Distinct terminals simplify identification of each grounded asset.

Green-and-yellow earth lead provides clear protective-ground recognition.

Locking ring, snap or banana interfaces suit common ESD equipment.

Optional resistance monitoring detects path interruption during operation.

Stainless or powder-coated hub enclosure suits controlled environments.

Modular cord lengths support benches, carts and equipment clusters.

Preocupaciones del producto del cliente

A grounding network must create a clear common reference without hidden series connections, unidentified leads or unreported interruptions.

Daisy-chained equipment creates uncertain resistance and a shared failure point.Each technical element connects independently to the central star point.
Ground cords are difficult to trace during audits.Numbered terminals and color-identified leads make every branch visible.
A disconnected ground can remain unnoticed between periodic checks.Optional continuous monitoring reports open or high-resistance paths immediately.
Mixed connector types encourage improvised adapters.Ring, snap, banana and locking connector interfaces are configured before installation.
Ordinary enclosures are difficult to clean in controlled rooms.Smooth stainless or powder-coated surfaces minimize ledges and simplify wipe-down.

Aplicaciones típicas

Cleanroom electronics assembly benches.Semiconductor process support areas.Medical-device electronics production.ESD-protected laboratories.Grounded material-transfer stations.Equipment service and inspection zones.

Parámetros técnicos

The representative configuration includes one common-point hub, protective-earth lead, four branch cords and a compact ground monitor. Connection count and monitoring method are selected from the cleanroom layout and risk assessment.

Materiales CoreStainless-steel or powder-coated steel hub with copper terminals, insulated conductors and electronic monitor
Panel de espesor1.2-2.0 mm hub-enclosure wall thickness
Ancho efectivo180-450 mm representative common-point panel width
Longitud máximaUp to 10000 mm per branch grounding lead
Acero frente a espesor1.2-2.0 mm stainless or coated-steel enclosure thickness
Densidad Core7800-8000 kg/m³ representative stainless-steel enclosure density
Conductividad térmica14-17 W/(m·K) representative stainless-steel enclosure range
Superficie acabadaBrushed stainless steel or smooth light-gray powder coating with engraved terminal labels
Tipo conjuntoStar-connected common-point terminals with ring lug, 10 mm snap, banana jack or locking plug interfaces
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Four-, eight- or twelve-way common-point hub.Passive or continuously monitored configuration.Brushed stainless or powder-coated enclosure.Custom cable lengths and terminal labels.Ring lug, banana jack, snap and locking connectors.Bench, wall or DIN-rail mounting.Remote alarm relay or facility-monitoring output.

Planning a Cleanroom ESD Grounding System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo