Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Sản phẩm ESD và chống tĩnh điện

Hệ thống nối đất ESD phòng sạch

The Cleanroom ESD Grounding System is a coordinated common-point network for bonding benches, mats, personnel connections and approved equipment to a verified protective earth.
  • Central common-point hub brings work surfaces, operators and compatible equipment to the same reference potential.
  • Clearly identified leads and locking connectors simplify installation, inspection and fault tracing.
  • Optional continuous monitoring provides immediate visual and audible warning of a broken ground path.
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The system centers on a wall- or bench-mounted metal common-point hub with individually identified terminals. A green-and-yellow protective-earth lead connects the hub to a verified facility ground. Separate cords serve work surfaces, floor elements and personnel connection blocks so each path can be inspected without daisy chaining. An optional monitor supervises selected conductors and reports open or high-resistance conditions through status lamps and an audible alarm.

Các tính năng chính

Star-topology common point avoids series-connected workstation elements.

Distinct terminals simplify identification of each grounded asset.

Green-and-yellow earth lead provides clear protective-ground recognition.

Locking ring, snap or banana interfaces suit common ESD equipment.

Optional resistance monitoring detects path interruption during operation.

Stainless or powder-coated hub enclosure suits controlled environments.

Modular cord lengths support benches, carts and equipment clusters.

Các mối quan tâm về sản phẩm của khách hàng

A grounding network must create a clear common reference without hidden series connections, unidentified leads or unreported interruptions.

Daisy-chained equipment creates uncertain resistance and a shared failure point.Each technical element connects independently to the central star point.
Ground cords are difficult to trace during audits.Numbered terminals and color-identified leads make every branch visible.
A disconnected ground can remain unnoticed between periodic checks.Optional continuous monitoring reports open or high-resistance paths immediately.
Mixed connector types encourage improvised adapters.Ring, snap, banana and locking connector interfaces are configured before installation.
Ordinary enclosures are difficult to clean in controlled rooms.Smooth stainless or powder-coated surfaces minimize ledges and simplify wipe-down.

Các ứng dụng điển hình

Cleanroom electronics assembly benches.Semiconductor process support areas.Medical-device electronics production.ESD-protected laboratories.Grounded material-transfer stations.Equipment service and inspection zones.

Thông số kỹ thuật

The representative configuration includes one common-point hub, protective-earth lead, four branch cords and a compact ground monitor. Connection count and monitoring method are selected from the cleanroom layout and risk assessment.

Vật liệu lõiStainless-steel or powder-coated steel hub with copper terminals, insulated conductors and electronic monitor
Độ dày bảng điều khiển1.2-2.0 mm hub-enclosure wall thickness
Chiều rộng hiệu quả180-450 mm representative common-point panel width
Chiều dài tối đaUp to 10000 mm per branch grounding lead
Thép đối mặt với độ dày1.2-2.0 mm stainless or coated-steel enclosure thickness
Mật độ lõi7800-8000 kg/m³ representative stainless-steel enclosure density
Độ dẫn nhiệt14-17 W/(m·K) representative stainless-steel enclosure range
Kết thúc bề mặtBrushed stainless steel or smooth light-gray powder coating with engraved terminal labels
Loại khớp nốiStar-connected common-point terminals with ring lug, 10 mm snap, banana jack or locking plug interfaces
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Four-, eight- or twelve-way common-point hub.Passive or continuously monitored configuration.Brushed stainless or powder-coated enclosure.Custom cable lengths and terminal labels.Ring lug, banana jack, snap and locking connectors.Bench, wall or DIN-rail mounting.Remote alarm relay or facility-monitoring output.

Planning a Cleanroom ESD Grounding System specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ