Autoclave de Bioseguridad Doble Puerta

A pass-through biocontainment steam autoclave built around a jacketed 316L square chamber, opposing automatic vertical-sliding doors, a continuous building bioseal, separate controls at both ends, filtered air removal and a closed condensate-retention path.
  • Opposing Vertical-Sliding Doors
  • Jacketed 316L Square Chamber
  • Continuous Building Bioseal
  • Filtered Exhaust and Closed Effluent Path
Solicite un presupuesto. Browse productos

Introducción del producto

The Biosafety Double-Door Autoclave is a through-wall steam-processing barrier for compatible laboratory loads moving out of a controlled containment zone. Its rectangular 316L pressure chamber is surrounded by a sectional jacket and terminates in automatic vertical-sliding doors at opposite ends, rather than two doors on one face. A continuous external bioseal closes the interface between the sterilizer body and the building opening, while separate compression gaskets seal the two pressure doors. Each end has its own HMI and door-status controls; the interlock prevents both doors from opening together and retains the receiving-side door until the configured cycle-release conditions are satisfied. Removed air passes through a dedicated HEPA housing, and chamber condensate enters a closed effluent-retention module instead of an open drain bottle. The illustrated floor-mounted arrangement uses four adjustable leveling feet plus an organized service-side run of stainless piping, isolation valves and blue manual handles. Chamber size, process recipe, exhaust-filter treatment, effluent hold logic and release criteria must be selected and verified for the actual load and facility risk assessment.

Características clave

Opposing automatic vertical-sliding doors keep the loading openings clear of swing arcs and enforce a true through-chamber material route between the containment and receiving sides.

The external bioseal flange and elastomeric wall gasket maintain the building barrier independently of the two pressure-door seals around the chamber openings.

A dedicated HEPA-filtered air-removal path and closed condensate-retention module keep exhaust and liquid effluent within configured treatment routes before release.

Separate near-side and far-side controls display cycle and door status at both ends, avoiding routine operator travel through the room boundary to operate the opposite face.

Preocupaciones del producto del cliente

A biosafety pass-through autoclave must protect the room barrier not only at its doors, but also along the wall interface, filtered air-removal route and condensate discharge path.

Doors placed on the same face, or two opposing doors that can open together, would create an uncontrolled shortcut across the containment boundary.The selected chamber has one vertical-sliding door at each opposite end, with a one-door-at-a-time interlock and receiving-side release logic tied to configured cycle conditions.
Air removed from porous waste or sealed laboratory loads can carry aerosols into an unprotected service exhaust line.The air-removal route passes through a dedicated service-side HEPA housing that can be configured for in-situ treatment and integrity-test access.
Chamber condensate sent directly to an open drain or bottle can bypass the intended biocontainment process boundary.A closed stainless effluent module retains and conditions condensate within an isolated valve path until the configured discharge criteria are met.
A single control station forces staff to cross zones or rely on verbal confirmation before loading and unloading.Independent HMIs and door-status indication at the two opposite ends provide local operating information while the interlock preserves the barrier sequence.

Aplicaciones típicas

Decontamination processing of compatible bagged laboratory waste before removal from a containment suiteBarrier handling of cages, bedding and washable animal-facility components selected for moist-heat treatmentSteam processing of compatible glassware, culture media and laboratory utensils in microbiology facilitiesPass-through movement from a controlled hot side to a clean or service side under a site-developed cycle and release procedure

Parámetros técnicos

Representative configurable construction values for the illustrated floor-mounted, medium-capacity vertical-door biosafety arrangement are listed below.

Materiales CoreAISI 316L stainless-steel rectangular pressure chamber and sectional jacket, 316L process and effluent piping, replaceable door gaskets and a stainless bioseal flange with an elastomeric wall seal
Panel de espesor50 mm nominal insulated external service-panel assembly for the selected floor-mounted configuration
Ancho efectivo672 mm usable chamber width for the selected medium-capacity square-section configuration
Longitud máximaUp to 1350 mm usable chamber depth within the selected automatic vertical-door configuration
Acero frente a espesor1.2 mm nominal white powder-coated external steel facing
Densidad Core8000 kg/m³ for representative AISI 316L stainless-steel components
Conductividad térmica15 W/(m·K) for representative AISI 316L stainless steel at 20 °C
Superficie acabadaPolished neutral-silver 316L chamber and piping, satin stainless doors, white powder-coated outer panels, black bioseal and door gaskets, dark-blue HMIs, red emergency stops, green status lamps and blue valve handles
Tipo conjuntoFully welded jacketed pressure chamber with gasket-compression vertical-sliding doors at opposite ends, an external building bioseal, sealed HEPA exhaust connections and a closed condensate-effluent valve path
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Alternative square-chamber widths, heights and depths within the automatic vertical-door rangeRemovable shelf racks, guided loading trolleys and floor- or pit-mounted loading arrangementsSingle or redundant exhaust-filter stages with in-situ steam treatment and filter integrity-test provisionsEffluent-retention capacity, jacket cooling, integral steam generation, dual bioseal monitoring and facility alarm interfaces