ชีวภาพความปลอดภัย Double-Door Autoclave
- Opposing Vertical-Sliding Doors
- Jacketed 316L Square Chamber
- Continuous Building Bioseal
- Filtered Exhaust and Closed Effluent Path
การแนะนําสินค้า
The Biosafety Double-Door Autoclave is a through-wall steam-processing barrier for compatible laboratory loads moving out of a controlled containment zone. Its rectangular 316L pressure chamber is surrounded by a sectional jacket and terminates in automatic vertical-sliding doors at opposite ends, rather than two doors on one face. A continuous external bioseal closes the interface between the sterilizer body and the building opening, while separate compression gaskets seal the two pressure doors. Each end has its own HMI and door-status controls; the interlock prevents both doors from opening together and retains the receiving-side door until the configured cycle-release conditions are satisfied. Removed air passes through a dedicated HEPA housing, and chamber condensate enters a closed effluent-retention module instead of an open drain bottle. The illustrated floor-mounted arrangement uses four adjustable leveling feet plus an organized service-side run of stainless piping, isolation valves and blue manual handles. Chamber size, process recipe, exhaust-filter treatment, effluent hold logic and release criteria must be selected and verified for the actual load and facility risk assessment.
คุณสมบัติที่สําคัญ
The external bioseal flange and elastomeric wall gasket maintain the building barrier independently of the two pressure-door seals around the chamber openings.
A dedicated HEPA-filtered air-removal path and closed condensate-retention module keep exhaust and liquid effluent within configured treatment routes before release.
Separate near-side and far-side controls display cycle and door status at both ends, avoiding routine operator travel through the room boundary to operate the opposite face.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
A biosafety pass-through autoclave must protect the room barrier not only at its doors, but also along the wall interface, filtered air-removal route and condensate discharge path.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
Representative configurable construction values for the illustrated floor-mounted, medium-capacity vertical-door biosafety arrangement are listed below.
| วัสดุหลัก | AISI 316L stainless-steel rectangular pressure chamber and sectional jacket, 316L process and effluent piping, replaceable door gaskets and a stainless bioseal flange with an elastomeric wall seal |
|---|---|
| ความหนาของแผง | 50 mm nominal insulated external service-panel assembly for the selected floor-mounted configuration |
| ความกว้างที่มีประสิทธิภาพ | 672 mm usable chamber width for the selected medium-capacity square-section configuration |
| ความยาวสูงสุด | Up to 1350 mm usable chamber depth within the selected automatic vertical-door configuration |
| ความหนาของเหล็กหันหน้า | 1.2 mm nominal white powder-coated external steel facing |
| ความหนาแน่นหลัก | 8000 kg/m³ for representative AISI 316L stainless-steel components |
| การนําความร้อน | 15 W/(m·K) for representative AISI 316L stainless steel at 20 °C |
| เสร็จสิ้นพื้นผิว | Polished neutral-silver 316L chamber and piping, satin stainless doors, white powder-coated outer panels, black bioseal and door gaskets, dark-blue HMIs, red emergency stops, green status lamps and blue valve handles |
| ประเภทร่วม | Fully welded jacketed pressure chamber with gasket-compression vertical-sliding doors at opposite ends, an external building bioseal, sealed HEPA exhaust connections and a closed condensate-effluent valve path |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่