A closed glove-access isolator arranged for sterility testing workflows, controlled sample entry and separate removal of liquid and solid waste.
  • Dedicated Sterility Test Layout
  • Dual-Operator Glove Access
  • Controlled Sample Transfer
  • Separated Waste Removal
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The sterility test isolator separates test samples and media from operators and the surrounding laboratory. One or two glove-access work chambers can support membrane filtration, direct inoculation or compatible rapid methods. Samples enter through a bio-decontamination hatch or rapid transfer port, and liquid and solid waste leave through dedicated closed routes. The chamber uses filtered airflow, welded stainless surfaces and pressure monitoring to maintain the selected test environment and reduce false-positive contamination risk.

Ciri-ciri Utama

Glove positions are spaced for simultaneous sample opening and test manipulation.

A dedicated transfer hatch separates load preparation from the main test chamber.

Separate liquid and solid waste interfaces prevent waste crossing the clean sample route.

A common control system monitors pressure, airflow and optional bio-decontamination cycles.

Radiused stainless interiors keep membrane-filtration equipment accessible for cleaning.

Kebimbangan Produk Pelanggan

Sterility testing needs both contamination prevention and a workflow that keeps sample entry, test manipulation and waste removal from crossing each other.

Room-borne contamination creates false-positive test results.A closed filtered chamber and controlled transfer path isolate the test from the laboratory.
Two operators cannot reach the same test setup efficiently.Paired glove positions and a long work zone support parallel manipulation.
Waste removal crosses the incoming sample path.Dedicated liquid and solid waste ports separate egress from sample loading.
Test equipment creates inaccessible surfaces.Removable supports and radiused internal geometry preserve cleaning access.

Permohonan yang biasa

Sterile drug sterility testingMedical-device sterility testingMembrane filtration methodsDirect inoculation procedures

Parameter teknikal

Typical configurable construction ranges for a sterility test isolator are listed below.

Bahan TerasFully welded SUS316L test chamber with laminated safety glass and CSM glove-sleeve assemblies
Ketebalan Panel50-100 mm double-skin chamber and air-handling sections
Lebar berkesan1800-4500 mm usable test-chamber width
Panjang maksimumUp to 6500 mm overall isolator length
Keluli Menghadapi Ketebalan2.0-3.0 mm SUS316L chamber shell; 1.2-1.5 mm service skins
Ketumpatan terasApproximately 8000 kg/m³ for SUS316L chamber material
Kekonduksian Terma14-16 W / (m · K) untuk keluli tahan karat austenit
Kemasan permukaanElectropolished SUS316L test chamber with welded radiused transitions
Jenis BersatuPressure-tight welded chamber with sealed glove rings, transfer hatch and separate waste interfaces
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Single- or dual-operator chamberIntegrated vapor bio-decontaminationRapid transfer portsMembrane filtration and waste handling modules