멸균 테스트 격리기

A closed glove-access isolator arranged for sterility testing workflows, controlled sample entry and separate removal of liquid and solid waste.
  • Dedicated Sterility Test Layout
  • Dual-Operator Glove Access
  • Controlled Sample Transfer
  • Separated Waste Removal
견적 요청 제품 찾아보기

상품 소개

The sterility test isolator separates test samples and media from operators and the surrounding laboratory. One or two glove-access work chambers can support membrane filtration, direct inoculation or compatible rapid methods. Samples enter through a bio-decontamination hatch or rapid transfer port, and liquid and solid waste leave through dedicated closed routes. The chamber uses filtered airflow, welded stainless surfaces and pressure monitoring to maintain the selected test environment and reduce false-positive contamination risk.

주요 기능

Glove positions are spaced for simultaneous sample opening and test manipulation.

A dedicated transfer hatch separates load preparation from the main test chamber.

Separate liquid and solid waste interfaces prevent waste crossing the clean sample route.

A common control system monitors pressure, airflow and optional bio-decontamination cycles.

Radiused stainless interiors keep membrane-filtration equipment accessible for cleaning.

고객 제품 관심사

Sterility testing needs both contamination prevention and a workflow that keeps sample entry, test manipulation and waste removal from crossing each other.

Room-borne contamination creates false-positive test results.A closed filtered chamber and controlled transfer path isolate the test from the laboratory.
Two operators cannot reach the same test setup efficiently.Paired glove positions and a long work zone support parallel manipulation.
Waste removal crosses the incoming sample path.Dedicated liquid and solid waste ports separate egress from sample loading.
Test equipment creates inaccessible surfaces.Removable supports and radiused internal geometry preserve cleaning access.

일반적인 응용 프로그램

Sterile drug sterility testingMedical-device sterility testingMembrane filtration methodsDirect inoculation procedures

기술 매개변수

Typical configurable construction ranges for a sterility test isolator are listed below.

핵심 재료Fully welded SUS316L test chamber with laminated safety glass and CSM glove-sleeve assemblies
패널 두께50-100 mm double-skin chamber and air-handling sections
유효 폭1800-4500 mm usable test-chamber width
최대 길이Up to 6500 mm overall isolator length
강철 면면 두께2.0-3.0 mm SUS316L chamber shell; 1.2-1.5 mm service skins
코어 밀도Approximately 8000 kg/m³ for SUS316L chamber material
열전도도 (Thermal Conductivity)14 - 16 W / (m · K) 오스테나이트 스테인레스 스틸
표면 마무리Electropolished SUS316L test chamber with welded radiused transitions
접합 유형Pressure-tight welded chamber with sealed glove rings, transfer hatch and separate waste interfaces
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Single- or dual-operator chamberIntegrated vapor bio-decontaminationRapid transfer portsMembrane filtration and waste handling modules