Kotak Plenum Pengedaran Udara Bilik Bersih
- Pressure Equalization
- Gasketed Duct Spigot
- Terminal-Wide Air Distribution
- Accessible Balancing Module
Pengenalan Produk
The cleanroom air distribution plenum box sits between a branch duct and the larger face of a diffuser or grille. Its internal volume reduces inlet velocity and allows pressure to spread before air reaches the terminal, preventing concentrated discharge beneath the spigot. Galvanized or stainless sheet construction forms a sealed path with a gasketed round connection, and an optional removable measuring damper provides room-side balancing. Non-fibrous or faced acoustic lining can reduce duct noise where the material is isolated from the clean airstream.
Ciri-ciri Utama
A rubber-sealed round spigot limits leakage at the branch duct connection.
Removable measurement and adjustment modules allow balancing through the diffuser opening.
Square, rectangular and full-length linear configurations match different cleanroom air terminals.
Kebimbangan Produk Pelanggan
A direct duct connection can leave a large diffuser face starved at the edges and noisy at the center unless velocity is equalized first.
Permohonan yang biasa
Parameter teknikal
Typical materials and dimensional ranges for a cleanroom diffuser or grille plenum box are listed below.
| Bahan Teras | Galvanized-steel or 304 stainless-steel box with optional faced polyester-fibre sound attenuation |
|---|---|
| Ketebalan Panel | 0.8–1.2 mm folded and sealed plenum panels |
| Lebar berkesan | 200–1200 mm terminal connection width |
| Panjang maksimum | Up to 2000 mm per linear plenum section |
| Keluli Menghadapi Ketebalan | 0.8–1.2 mm galvanized or stainless plenum sheet |
| Ketumpatan teras | Approximately 7850 kg/m³ for the steel plenum casing |
| Kekonduksian Terma | Approximately 45–60 W/(m·K) for the steel plenum casing |
| Kemasan permukaan | Clean galvanized finish, white powder coat or brushed 304 stainless steel |
| Jenis Bersatu | Folded sealed box seams with gasketed round spigot and flanged terminal connection |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Cleanroom Air Distribution Plenum Box specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)