클린룸 HVAC 및 공기 처리 장비
패키지형 온수 난방장치
A factory-arranged hydronic skid that transfers heat into a cleanroom heating loop and circulates it through air-handler coils at controlled temperature.
- Complete Hydronic Skid
- Plate-Exchanger Circuit Separation
- Integrated Pump and Expansion
- Visible Operating Instruments
상품 소개
The unit groups a gasketed plate heat exchanger, in-line circulation pump, expansion vessel, control valves, gauges, manifolds and electrical cabinet on one rigid skid. Primary hot water or steam heats a separate secondary loop without mixing the fluids. The integrated pump maintains coil circulation while the control valve modulates heat input to a defined supply-water temperature.
주요 기능
Plate channels physically separate the primary heat source from the cleanroom heating-water circuit.
A dedicated in-line pump maintains stable secondary flow as the primary control valve modulates.
Pressure, temperature and flow instruments are visible from the service side for rapid operating checks.
고객 제품 관심사
A secondary heating loop needs hydraulic separation, stable temperature and maintainable components within limited plant space.
Primary plant water chemistry is unsuitable for sensitive secondary equipment.A gasketed plate exchanger keeps the primary and cleanroom heating loops physically separate.
Field-installed components occupy excessive space and have inconsistent access.The complete pump, exchanger, vessel and valve arrangement is organized on one serviceable skid.
Changing primary temperature causes unstable coil supply water.A modulating valve regulates heat input while the secondary pump maintains constant circulation.
Expansion pressure and trapped air interrupt hydronic flow.An integrated expansion vessel, air vent and fill connection stabilize the closed secondary circuit.
일반적인 응용 프로그램
Cleanroom AHU heating loopsPharmaceutical secondary hot-water circuitsHospital laboratory ventilationHeat-recovery interface stationsBoiler-to-low-temperature hydronic conversion
기술 매개변수
Typical physical construction data for a packaged secondary heating-water unit are shown below.
| 핵심 재료 | Carbon-steel skid with AISI 304 or 316 stainless plate exchanger, cast-iron pump and stainless manifolds |
|---|---|
| 패널 두께 | 8-16 mm fabricated steel skid and mounting plate thickness |
| 유효 폭 | 800-1800 mm typical skid width |
| 최대 길이 | Up to 3600 mm overall skid length |
| 강철 면면 두께 | 1.2-2.0 mm electrical cabinet sheet |
| 코어 밀도 | Approximately 7900-8000 kg/m³ for the austenitic stainless steel heat-exchanger plate pack |
| 열전도도 (Thermal Conductivity) | Approximately 14-16 W/(m·K) for the austenitic stainless steel exchanger plates |
| 표면 마무리 | Epoxy-coated black base with painted components and stainless manifolds |
| 접합 유형 | Welded skid and manifolds with flanged pump, exchanger and valve connections |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Steam-to-water or water-to-water heat sourceSingle or duty-standby secondary pumpsTwo-way or three-way primary control valveInsulated piping, flow meter and remote communications
Planning a Packaged Hot-Water Heating Unit specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

영어
독일어
아랍어
프랑스어
인도네시아어
일본어
한국어현재 Current
말레이어
포르투갈어
러시아어
스페인어
태국어
터키어