클린룸 HVAC 및 공기 처리 장비
유도형 역류 냉각탑
A compact evaporative heat-rejection tower that draws air upward through wetted fill while condenser water descends into an accessible collection basin.
- Counterflow Air-Water Contact
- Top-Mounted Induced Draft
- Corrosion-Resistant FRP Shell
- Serviceable Fill and Basin
상품 소개
The induced-draft counterflow tower uses a top axial fan to draw ambient air upward against warm condenser water distributed above the fill. Evaporation removes heat before cooled water collects in the lower basin and returns to the refrigeration plant. A square FRP casing, removable louvers and modular fill pack provide a compact alternative to crossflow arrangements where footprint matters.
주요 기능
The fan at the discharge draws air uniformly through lower inlet louvers and reduces recirculation at the intake.
FRP casing panels and stainless support members resist continuous wet service and treatment chemistry.
Access doors, removable fill cassettes and an open basin support inspection of water-contact components.
고객 제품 관심사
A cooling tower must reject the design load while controlling footprint, water distribution and maintenance access.
Limited roof area restricts the size of heat-rejection equipment.A vertical counterflow path concentrates fill depth and fan discharge within a compact square plan.
Uneven spray distribution leaves dry fill zones and reduces capacity.A full-coverage header and serviceable nozzles wet the modular fill pack uniformly.
Drift can carry treatment chemicals beyond the tower.Dedicated drift eliminators change exhaust-air direction and capture entrained droplets.
Basin sediment blocks strainers and accelerates corrosion.Accessible sloped basin surfaces, drain points and removable strainers simplify routine cleaning.
일반적인 응용 프로그램
Cleanroom chiller condenser-water systemsPharmaceutical process-cooling loopsHospital central plantsElectronics-factory HVACIndustrial refrigeration heat rejection
기술 매개변수
Representative physical construction ranges for a modular counterflow tower are listed below.
| 핵심 재료 | PVC fill media inside fiber-reinforced polymer casing |
|---|---|
| 패널 두께 | 3-6 mm molded FRP casing panel thickness |
| 유효 폭 | 1000-3200 mm nominal tower cell width |
| 최대 길이 | Up to 6500 mm for multi-cell assemblies |
| 강철 면면 두께 | 1.5-3.0 mm stainless or hot-dip-galvanized basin/support sheet |
| 코어 밀도 | 30-60 kg/m³ typical PVC fill-pack density |
| 열전도도 (Thermal Conductivity) | Approximately 0.19 W/(m·K) for rigid PVC fill material |
| 표면 마무리 | Smooth UV-stabilized FRP exterior with passivated or galvanized hardware |
| 접합 유형 | Bolted gasketed casing panels with modular clipped fill cassettes and flanged water ports |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |