상품 소개
The cleanroom socket replaces a projecting domestic outlet with a recessed stainless or coated-steel service plate. Its selected receptacle module is mounted through the plate, the perimeter gasket remains hidden behind the flange, and a sealed rear box contains terminals and cable entries. The plate can carry one or more outlets while maintaining an even wall plane around each device.
주요 기능
A concealed gasket seals the complete plate perimeter without an external bead.
Colored inserts distinguish voltage or circuit purpose at a glance.
The rear box separates live terminals from the cleanroom cavity.
Countersunk retained fasteners keep the exposed surface smooth.
고객 제품 관심사
Power outlets must remain accessible without creating deep recesses, open wall cavities or ambiguous circuit identification.
A domestic outlet frame leaves multiple dirt-catching ledges.One flat sanitary plate surrounds the complete receptacle module.
Cleaning liquid enters an open wall box.The rear enclosure and cable gland isolate wiring from the room-side opening.
Users connect equipment to the wrong voltage circuit.Color, pin pattern and engraved circuit labels differentiate the supply.
Exposed perimeter sealant tears during repeated wiping.The primary gasket sits concealed behind the rigid faceplate flange.
일반적인 응용 프로그램
Cleanroom equipment outletsLaboratory bench powerGowning room utilitiesControlled-area housekeeping circuits
기술 매개변수
Typical configurable construction ranges for a cleanroom electrical socket are listed below.
| 핵심 재료 | SUS304 or SUS316L faceplate with engineering-polymer receptacle insert and steel rear wiring box |
|---|---|
| 패널 두께 | 1.5-3.0 mm hygienic front-plate thickness |
| 유효 폭 | 120-300 mm faceplate width |
| 최대 길이 | Up to 400 mm overall plate height for multi-outlet layouts |
| 강철 면면 두께 | 1.5-3.0 mm stainless room-side plate |
| 코어 밀도 | Approximately 7900-8000 kg/m³ for austenitic stainless faceplate material |
| 열전도도 (Thermal Conductivity) | 14-16 W/(m·K) for the stainless faceplate |
| 표면 마무리 | Fine-brushed or electropolished stainless with colored polymer outlet insert |
| 접합 유형 | Flush recessed plate with concealed perimeter gasket, sealed rear box and cable gland |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Single, duplex or multi-gang outletIEC, regional or pin-and-sleeve receptacleCircuit color and laser markingStainless or white coated plate
Planning a Cleanroom Electrical Socket specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

영어
독일어
아랍어
프랑스어
인도네시아어
일본어
한국어현재 Current
말레이어
포르투갈어
러시아어
스페인어
태국어
터키어
베트남어