クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
FFU およびターミナル空気浄化装置

ステンレス鋼ファンのフィルターユニット

An all-welded brushed stainless steel FFU with sealed seams and cleanable hardware for sanitary, chemical-resistant or frequently wiped cleanroom ceilings.
  • All-Welded Stainless Housing
  • Cleanable Brushed Surfaces
  • Sealed Hygienic Corners
  • Room-Side Service Option
見積もりリクエスト 製品案内

商品紹介

The stainless steel fan filter unit encloses the blower, pressure chamber and final filter in a formed 304 or 316 stainless casing. Continuous welded corner seams remove overlapping raw edges from exposed surfaces, and the brushed grain gives cleaning staff a consistent wipe direction. Stainless latches, a silicone perimeter gasket and a perforated stainless diffuser support hygienic maintenance on both the service and cleanroom sides. The construction is suitable where painted steel would be vulnerable to repeated chemical wiping, moisture or process residues.

主要な特徴

Continuous welded seams close folded cavities that could otherwise retain moisture or cleaning residue.

A uniform brushed finish limits glare while leaving a smooth surface that can be wiped in a controlled direction.

Stainless latches and fasteners avoid mixed exposed materials around frequently handled service points.

An optional room-side filter arrangement permits removal without opening an inaccessible interstitial ceiling space.

お客様の製品に関する懸念事項

A hygienic FFU must tolerate repeated cleaning while preventing seams, coatings and mixed-metal hardware from becoming contamination traps.

Paint chips at service-panel edges expose corroding base metal above a critical clean zone.A stainless housing provides corrosion resistance through the sheet thickness instead of relying on a surface coating.
Folded overlaps and unsealed corners retain liquid after ceiling cleaning.Continuous welded seams and flush corner finishing remove open crevices from the exposed enclosure.
Aggressive disinfectants stain or soften ordinary painted diffusers and fasteners.A brushed stainless diffuser, latches and hardware present a consistent cleanable material system.
Ceiling access is limited in sealed pharmaceutical suites.A room-side service option allows the filter and selected fan components to be reached from the clean zone.

典型的な用途

Aseptic pharmaceutical productionBiotechnology processing rooms食品 · 飲料クリーンエリアHigh-humidity clean manufacturingFacilities using frequent chemical wipe-down

技術的なパラメータ

Typical materials and dimensional ranges for a hygienic stainless steel fan filter unit are provided below.

コア材料304 or 316 stainless-steel plenum, backward-curved EC fan and micro-glass HEPA or ULPA filter pack
パネルの厚さ300-420 mm overall module depth
有効幅575 — 1170 mm 公称天井グリッド幅
最大長さ最大 1170 mm 標準モジュール長
鋼鉄の厚さを直面する1.0-1.5 mm 304 or 316 stainless-steel housing sheet
コア密度Approximately 90-120 kg/m³ nominal compacted density of the micro-glass pack installed in the stainless-steel FFU
熱伝導率Approximately 0.035-0.043 W/(m·K) for the dry final-filter pack enclosed by the stainless-steel FFU
表面仕上げNo. 4 brushed stainless steel or optional electropolished exposed surfaces
ジョイントタイプAll-welded plenum with silicone ceiling gasket and gel-seal or compression-seal room-side filter interface
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

304 or 316 stainless steelNo. 4 brushed or electropolished finishTop-access or sanitary room-side service configurationStainless-framed HEPA or ULPA gel-seal filter

Planning a Stainless Steel Fan Filter Unit specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat