Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Instrumen pengujian dan validasi ruang bersih

Surface Temperature Meter (Meter Suhu Permukaan)

A handheld contact temperature meter with a single Type K thermocouple input and spring-band surface probe for direct checks on panels, pipes and equipment housings.
  • Direct Type K contact measurement.
  • Conforming spring-band surface probe.
  • Hold, minimum, maximum and average recall.
Permintaan untuk kutipan Browse Produk

Perkenalan produk

This contact surface temperature meter reads the thermoelectric voltage from a Type K probe and applies cold-junction compensation inside the handheld instrument. Its separate surface probe uses a thin resilient thermocouple strip that conforms to a flat or gently curved workpiece with light, repeatable pressure. A backlit LCD and direct-access hold, minimum, maximum and average functions support comparison of equipment surfaces without the emissivity uncertainty associated with non-contact infrared readings. The keyed miniature connector allows the meter to accept alternative compatible probes when air, immersion or narrow-access measurements are required.

Fitur utama:

Direct thermocouple contact measures the local surface without an infrared emissivity setting.

Spring-band sensing tip conforms to flat, slightly convex and mildly uneven surfaces under light pressure.

Single keyed Type K miniature input keeps polarity and probe replacement straightforward.

Backlit LCD with hold, minimum, maximum and average functions supports repeatable survey records.

Separate probe handle and flexible strain-relieved cable keep the operator's hand away from the test surface.

Protective TPE boot, rear kickstand and replaceable battery suit bench and field measurements.

Kekhawatiran produk pelanggan

Reliable contact readings depend on full sensor contact, consistent pressure, probe angle, response time and local heat flow, so the probe geometry and handling method should match the surface being checked.

Tilting the probe or applying inconsistent force can leave the sensing strip partly off the surface and slow or bias the reading.Use the spring-band head square to the surface with light repeatable pressure, and hold it steady until the display stabilizes.
A cold probe, moving air or nearby radiant heat can influence the initial indicated temperature.Allow the probe to acclimate, shield the contact point from drafts where practical, and compare readings under the same operating conditions.
One probe shape cannot make reliable contact with every flat plate, small component, pipe or narrow slot.Select a flat spring-band, small-head, right-angle paddle or pipe-clamp Type K probe to match the target geometry.
A contact probe can conduct heat away from a thin or low-mass surface during a long measurement.Use a low-mass fast-response contact strip, minimize dwell time after stabilization, and repeat the reading to check consistency.

Aplikasi yang Tipis

Cleanroom wall-panel and door-surface checksAir-handling cabinet and duct-skin temperature comparisonPipe, valve and heat-exchanger surface measurementMotor housing and bearing-cap temperature surveysHeated plate, sealing jaw and process-tool verification

Parameter teknis

Representative construction for a professional single-input surface temperature meter is listed below; probe shape, cable length, response time and working temperature range should be selected for the target material and access conditions.

Bahan intiPC/ABS handheld enclosure with TPE boot, LCD, silicone keypad, Type K miniature thermocouple socket, NiCr-Ni thermocouple conductors, spring-metal contact strip and stainless probe tube
Ketebalan Panel (Panel Thickness)Typically 2.0-3.0 mm for the molded meter enclosure wall
Efektif lebarApproximately 60-75 mm across the handheld meter
Panjang maksimumApproximately 165-190 mm for the meter body, excluding the detachable probe and cable
Baja menghadap ketebalanTypically 0.3-0.8 mm for the probe shell, spring contact, shielding and fasteners
Kepadatan inti (core density)Sekitar 1100 - 1200 kg / m3 untuk campuran PC / ABS enclosure
Konduktivitas Termal (Thermal Conductivity)Kira-kira 0,19 - 0,22 W / (m · K) untuk campuran PC / ABS
Permukaan selesaiBlue-gray fine-texture enclosure, black TPE protective boot, pale-green LCD, yellow Type K connector, black cable and satin-stainless probe tip
Jenis BersamaKeyed polarized Type K miniature socket with strain-relieved cable, angled stainless probe neck, resilient surface-contact strip, rear battery cover and folding kickstand
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Fast-response spring-band probe for flat and uneven surfacesSmall-head contact probe for compact componentsRight-angle paddle probe for narrow accessPipe-clamp Type K probe for round tubingExtended thermocouple cable with polarized miniature connectorsProtective case, spare battery and desktop support stand

Planning a Surface Temperature Meter specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami