Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Kontrol Cleanroom dan Sistem Pemantauan Lingkungan

Sistem Kontrol Airlock Interlock

A fail-defined airlock controller that prevents incompatible doors from opening together while providing clear occupancy, request and release status at each doorway.
  • Two-to-Four Door Logic
  • Visible Door Status
  • Timed Release Sequence
  • Emergency Override Input
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The airlock interlock control system supervises door contacts, electric locks, request buttons and status lamps for a controlled transition space. When one door opens or unlocks, the controller inhibits the incompatible doors until the first door is closed and the defined delay expires. Separate emergency and fire inputs apply the selected safe release behavior without obscuring event status. Remote contacts or network communication allow facility operators to see door position, lock state, forced-open alarms and override activity.

Fitur utama:

Configurable logic supports two-door airlocks and more complex three- or four-door sequences.

Distinct request, locked, available and alarm indications reduce occupant uncertainty.

Adjustable release delay lets room pressure recover before the next door can be used.

Dedicated emergency and fire inputs apply a documented fail-safe or fail-secure behavior.

Kekhawatiran produk pelanggan

An airlock must control door sequence without trapping occupants or creating ambiguous behavior during alarms and power loss.

Users repeatedly pull a locked door because its status is unclear.Color indicators and request acknowledgement show when each door is available or inhibited.
The next door releases before the pressure cascade has recovered.An adjustable closed-door delay holds the sequence until the airlock stabilizes.
A misaligned door contact leaves the airlock permanently blocked.Separate door-position and lock-status diagnostics identify the input preventing release.
Emergency release behavior is improvised at installation.Dedicated monitored inputs and selected fail mode define how each lock responds to emergency or fire conditions.

Aplikasi yang Tipis

Personnel airlocksMaterial airlocksPharmaceutical change roomsBio-containment transition zones

Parameter teknis

Typical construction for a cleanroom airlock interlock controller and doorway indicator set is listed below.

Bahan intiPowder-coated steel control enclosure with FR-4 logic board, copper lock relays and stainless indicator plates
Ketebalan Panel (Panel Thickness)120-250 mm enclosure depth
Efektif lebar300-600 mm control panel width
Panjang maksimumUp to 800 mm control enclosure height
Baja menghadap ketebalan1.2-1.5 mm powder-coated steel enclosure
Kepadatan inti (core density)7800-8050 kg/m³ for steel and stainless structural parts
Konduktivitas Termal (Thermal Conductivity)14-60 W/(m·K) across stainless indicator plates and steel enclosure parts
Permukaan selesaiLight-gray control box with brushed stainless door stations and red-green status lamps
Jenis BersamaGasketed controller with pluggable door, lock, request, alarm and emergency terminals
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Two, three or four-door logicFail-safe or fail-secure locksStainless door stationsBMS dry contact or network output

Planning a Airlock Interlock Control System specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah