Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Sistem Kawalan Bilik Bersih dan Pemantauan Alam Sekitar

Sistem Kawalan Interlock Airlock

A fail-defined airlock controller that prevents incompatible doors from opening together while providing clear occupancy, request and release status at each doorway.
  • Two-to-Four Door Logic
  • Visible Door Status
  • Timed Release Sequence
  • Emergency Override Input
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The airlock interlock control system supervises door contacts, electric locks, request buttons and status lamps for a controlled transition space. When one door opens or unlocks, the controller inhibits the incompatible doors until the first door is closed and the defined delay expires. Separate emergency and fire inputs apply the selected safe release behavior without obscuring event status. Remote contacts or network communication allow facility operators to see door position, lock state, forced-open alarms and override activity.

Ciri-ciri Utama

Configurable logic supports two-door airlocks and more complex three- or four-door sequences.

Distinct request, locked, available and alarm indications reduce occupant uncertainty.

Adjustable release delay lets room pressure recover before the next door can be used.

Dedicated emergency and fire inputs apply a documented fail-safe or fail-secure behavior.

Kebimbangan Produk Pelanggan

An airlock must control door sequence without trapping occupants or creating ambiguous behavior during alarms and power loss.

Users repeatedly pull a locked door because its status is unclear.Color indicators and request acknowledgement show when each door is available or inhibited.
The next door releases before the pressure cascade has recovered.An adjustable closed-door delay holds the sequence until the airlock stabilizes.
A misaligned door contact leaves the airlock permanently blocked.Separate door-position and lock-status diagnostics identify the input preventing release.
Emergency release behavior is improvised at installation.Dedicated monitored inputs and selected fail mode define how each lock responds to emergency or fire conditions.

Permohonan yang biasa

Personnel airlocksMaterial airlocksPharmaceutical change roomsBio-containment transition zones

Parameter teknikal

Typical construction for a cleanroom airlock interlock controller and doorway indicator set is listed below.

Bahan TerasPowder-coated steel control enclosure with FR-4 logic board, copper lock relays and stainless indicator plates
Ketebalan Panel120-250 mm enclosure depth
Lebar berkesan300-600 mm control panel width
Panjang maksimumUp to 800 mm control enclosure height
Keluli Menghadapi Ketebalan1.2-1.5 mm powder-coated steel enclosure
Ketumpatan teras7800-8050 kg/m³ for steel and stainless structural parts
Kekonduksian Terma14-60 W/(m·K) across stainless indicator plates and steel enclosure parts
Kemasan permukaanLight-gray control box with brushed stainless door stations and red-green status lamps
Jenis BersatuGasketed controller with pluggable door, lock, request, alarm and emergency terminals
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Two, three or four-door logicFail-safe or fail-secure locksStainless door stationsBMS dry contact or network output

Planning a Airlock Interlock Control System specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami