Oposé Amortisseur de contrôle de volume de lame
- True Opposed Blade Action
- External Linkage
- Low-Leakage Edge Seals
- Manual or Motorized Drive
Introduction de produit
The opposed blade volume control damper regulates air through rectangular cleanroom branches, equipment inlets and wall openings. Alternating aerofoil blades rotate toward and away from each other through an external linkage, dividing the throttling effect across the full face rather than concentrating it at one edge. A rigid channel frame keeps blade shafts aligned, while tip and side seals reduce closed-position leakage. The drive remains outside the airstream and can accept a manual quadrant, electric actuator or pneumatic operator.
Key Features
External linkage keeps moving joints out of the primary air path and visible for inspection.
Formed aerofoil blades resist vibration and reduce pressure loss when fully open.
Side and blade-tip seals limit bypass when the damper is used for branch isolation.
Préoccupations du client produit
A balancing damper must provide stable modulation without blade chatter, distorted downstream flow or excessive closed-position leakage.
Les applications typiques
Paramètres techniques
Representative material and dimensional ranges for a rectangular opposed blade control damper are listed below.
| Matériaux de base | Galvanized-steel or 304 stainless-steel channel frame with linked double-skin aerofoil blades |
|---|---|
| Panneau épaisseur | 1.0–2.0 mm frame channels and double-skin blade sheets |
| Largeur effective | 200–2000 mm nominal single-section width |
| Longueur maximale | Up to 2000 mm single-section width, with subdivided assemblies for larger openings |
| Acier face épaisseur | 1.0–2.0 mm galvanized or stainless frame and blade material |
| Densité Core | Approximately 7850 kg/m³ for galvanized-steel frame and blade construction |
| Conductivité thermique | Approximately 45–60 W/(m·K) for galvanized-steel frame and blade construction |
| surface finie | Mill-galvanized, white powder-coated or brushed stainless-steel finish |
| Type joint | Flanged rectangular frame with external opposed-action linkage and sealed blade edges |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Opposed Blade Volume Control Damper specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien