Z Chauffage Coil
- One- or Two-Row Heating Core
- Copper Water Circuit
- Low Airside Depth
- Service-Side Threaded Unions
Introduction de produit
The heating coil is a compact hydronic heat exchanger installed upstream or downstream of other AHU treatment stages to raise dry-bulb air temperature. Hot water flows through parallel copper tubes mechanically expanded into aluminum plate fins, and a shallow galvanized casing supports the assembly at the air-handler opening. Heating duty commonly requires fewer tube rows than a chilled-water cooling section, reducing core depth and air resistance where the selected entering-water temperature permits. Replacement selection must match the original face dimensions, tube-row count, circuit arrangement, connection orientation and required sensible heating performance.
Key Features
Mechanically expanded copper tubes maintain direct thermal contact with the continuous aluminum fin surface.
A rigid galvanized frame and corner mounting ears provide defined support at the AHU or duct opening.
The accessible copper header groups the hot-water supply and return connections on one service side.
Préoccupations du client produit
A replacement heating coil must provide the required sensible capacity without excessive water resistance, air pressure drop or freeze exposure.
Les applications typiques
Paramètres techniques
The ranges below describe typical material and envelope choices for compact water-fed air reheating sections.
| Matériaux de base | Seamless copper water tubes mechanically expanded into continuous aluminum plate fins |
|---|---|
| Panneau épaisseur | 45-180 mm nominal coil depth for common one- or two-row heating selections |
| Largeur effective | 300-2200 mm nominal finned face width |
| Longueur maximale | Up to 2800 mm overall casing length for common AHU replacement sections |
| Acier face épaisseur | 1.0-1.6 mm galvanized-steel casing and mounting-ear thickness |
| Densité Core | Approximately 8900-8960 kg/m³ for copper tube and header components |
| Conductivité thermique | Approximately 380-400 W/(m·K) for copper heat-transfer tubes |
| surface finie | Natural galvanized-silver casing and aluminum fins with copper header and brass female threaded unions |
| Type joint | Mechanically expanded tube-to-fin bond with brazed copper circuits and female threaded header connections |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Heating Coil specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.