클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 장비 예비 부품

난방 코일 (Heating Coil)

A shallow finned-tube hot-water coil for restoring sensible preheat or reheat duty in a matched cleanroom air-handling unit.
  • One- or Two-Row Heating Core
  • Copper Water Circuit
  • Low Airside Depth
  • Service-Side Threaded Unions
견적 요청 제품 찾아보기

상품 소개

The heating coil is a compact hydronic heat exchanger installed upstream or downstream of other AHU treatment stages to raise dry-bulb air temperature. Hot water flows through parallel copper tubes mechanically expanded into aluminum plate fins, and a shallow galvanized casing supports the assembly at the air-handler opening. Heating duty commonly requires fewer tube rows than a chilled-water cooling section, reducing core depth and air resistance where the selected entering-water temperature permits. Replacement selection must match the original face dimensions, tube-row count, circuit arrangement, connection orientation and required sensible heating performance.

주요 기능

A one- or two-row tube arrangement provides a shallow heating section for preheat and reheat duties.

Mechanically expanded copper tubes maintain direct thermal contact with the continuous aluminum fin surface.

A rigid galvanized frame and corner mounting ears provide defined support at the AHU or duct opening.

The accessible copper header groups the hot-water supply and return connections on one service side.

고객 제품 관심사

A replacement heating coil must provide the required sensible capacity without excessive water resistance, air pressure drop or freeze exposure.

A deeper or more densely finned core consumes fan pressure that was not available in the original AHU.Tube rows and fin spacing are selected around the heating load, face velocity and allowable airside resistance.
Incorrect supply and return positions make the existing pipework difficult to reconnect and service.Header side, union orientation, center spacing and thread size are matched to the removed coil or verified equipment drawing.
Poor circuit distribution creates uneven leaving-air temperature across the coil face.Tube passes and header layout are arranged for balanced water flow across the selected face dimensions.
Stagnant water can freeze when cold outdoor air reaches an inactive preheat coil.The coil selection can incorporate suitable circuit velocity, vent and drain provisions, and compatible water-glycol service where required by the operating conditions.

일반적인 응용 프로그램

Cleanroom AHU preheat sectionsSupply-air reheat stagesMake-up air tempering unitsReplacement hot-water coil modules

기술 매개변수

The ranges below describe typical material and envelope choices for compact water-fed air reheating sections.

핵심 재료Seamless copper water tubes mechanically expanded into continuous aluminum plate fins
패널 두께45-180 mm nominal coil depth for common one- or two-row heating selections
유효 폭300-2200 mm nominal finned face width
최대 길이Up to 2800 mm overall casing length for common AHU replacement sections
강철 면면 두께1.0-1.6 mm galvanized-steel casing and mounting-ear thickness
코어 밀도Approximately 8900-8960 kg/m³ for copper tube and header components
열전도도 (Thermal Conductivity)Approximately 380-400 W/(m·K) for copper heat-transfer tubes
표면 마무리Natural galvanized-silver casing and aluminum fins with copper header and brass female threaded unions
접합 유형Mechanically expanded tube-to-fin bond with brazed copper circuits and female threaded header connections
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

One- or two-row constructionCustom face size and fin spacingLeft- or right-hand header arrangementOptional vent, drain and protective fin coating

Planning a Heating Coil specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat