EC Unité de ventilateur centrifuge d'alimentation en air de salle blanche
- Backward-Curved EC Impeller
- Stepless Airflow Adjustment
- Insulated Low-Leakage Cabinet
- Vibration-Isolated Fan Module
Introduction de produit
The EC centrifugal supply-air fan unit places a high-efficiency backward-curved impeller, electronically commutated motor, airflow sensing and flexible connections inside a rigid insulated cabinet. Direct drive removes belts and their wear particles, while variable speed allows the fan to compensate for filter loading or switch between occupied and setback airflow. Removable panels provide access to the wheel, motor electronics and isolation mounts from outside the air path.
Key Features
Integrated EC speed control accepts analog or network commands without an external variable-frequency drive for smaller fan sizes.
Flexible inlet and discharge connections prevent casing vibration from transferring into rigid cleanroom ductwork.
An insulated double-skin cabinet reduces breakout noise and limits condensation on the casing during cold supply-air operation.
Préoccupations du client produit
Cleanroom supply fans must overcome rising filter resistance while holding the scheduled airflow without adding unnecessary noise, vibration or maintenance debris.
Les applications typiques
Paramètres techniques
Typical construction ranges for an insulated EC centrifugal supply-air fan package are listed below.
| Matériaux de base | Aluminum or coated-steel backward-curved impeller in a mineral-wool-insulated galvanized steel cabinet |
|---|---|
| Panneau épaisseur | 30-50 mm double-skin acoustic and thermal panel thickness |
| Largeur effective | 800-2400 mm nominal fan-cabinet width |
| Longueur maximale | Up to 3500 mm for multi-fan or fan-plus-silencer assemblies |
| Acier face épaisseur | 0.8-1.2 mm pre-painted outer skin and galvanized inner skin |
| Densité Core | 40-80 kg/m³ typical mineral-wool cabinet insulation density |
| Conductivité thermique | Approximately 0.035-0.045 W/(m·K) for mineral-wool cabinet insulation |
| surface finie | White powder-coated frame with blue service doors and corrosion-resistant internal fan surfaces |
| Type joint | Bolted gasketed cabinet with flexible inlet and discharge connectors and vibration-isolated fan base |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a EC Centrifugal Cleanroom Supply-Air Fan Unit specification?