Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Cleanroom Installation Zubehör

Firestop Sealant

A flexible firestop joint compound for closing smoke paths at cleanroom construction joints and compatible penetration-system interfaces.
  • Smoke-Tight Joint Closure
  • Movement-Capable Seal
  • Low-Shrink Application
  • System-Compatible Detailing

Produkteinführung

Firestop sealant is a cartridge-applied compound used as the exposed seal component in tested wall, floor and service-penetration arrangements. The non-sag paste is tooled over the specified backing material to create a continuous smoke-resistant joint while retaining the movement capability needed at modular panel and building interfaces. Selection is based on the complete supporting construction, opening geometry and service conditions rather than on sealant alone.

Key Features

Non-sag consistency supports controlled installation in vertical and overhead joint openings.

Elastic grades accommodate cyclic movement at perimeter and construction joints.

Low-shrink curing helps preserve contact with prepared joint flanks.

Red or contrasting compounds make installed coverage easier to inspect before enclosure.

Kunden Produktbedenken

A fire-resisting cleanroom interface must close smoke paths while remaining compatible with the complete wall, backing and penetration arrangement.

Sealant selected independently of the supporting assembly may not suit the opening geometry.Joint width, depth, backing, substrates and services are matched as one defined firestop system.
Building movement can split a rigid perimeter seal and create a smoke path.A movement-capable grade and correct width-to-depth profile allow controlled elastic deformation.
Dust or weak coatings cause adhesion loss along joint flanks.Sound substrates are cleaned and, where required, primed before backing and sealant placement.
Inconsistent bead depth leaves thin sections around penetrations.Specified backing material controls depth and supports uniform tooling around the full opening.

Typische Anwendungen

Cleanroom wall-to-slab jointsFire-rated partition perimetersService-penetration annular sealsCable and pipe opening systemsSmoke-control construction joints

Technische Parameter

Typical construction and application ranges for an elastic cartridge-applied firestop joint sealant are listed below.

Core MaterialOne-component acrylic, silicone or hybrid firestop elastomer
Panel Dicke6-25 mm typical installed seal depth
Effektive Breite6-50 mm practical construction-joint width
Maximale LängeUp to 10000 mm continuous prepared joint section
Stahl facing Dicke0.50-1.50 mm compatible coated-steel panel facing
KerndichteApproximately 1300-1700 kg/m³ uncured compound density
Thermische LeitfähigkeitApproximately 0.20-0.50 W/(m·K) for cured sealant
Oberfläche FinishSmooth tooled red, white or gray elastomeric surface
Gemeinsamer TypBacked perimeter, construction or penetration annular joint within a compatible firestop assembly
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Red, white or gray compoundAcrylic or silicone chemistryCartridge or foil-pack supplyCompatible mineral-wool or backing system